390
3Z4L Laser Micrometer Protocol
Appendix K
416 (01A0)
Statistic processing execution
(3000-series)
Lights the statistic processing LED
and processes the statistics.
No
No
417 (01A1)
Statistic processing non-exe-
cution (3000-series)
Turns OFF the statistic processing
LED. Statistics are not processed.
No
No
418 (01A2)
All statistic memory clear
(3000-series)
Clears statistic processing memories
of all programs.
No
No
419 (01A3)
Statistic memory clear
(3000-series)
Clears statistic processing memories
of program under display.
No
No
420 (01A4)
Statistic result request
(3000-series)
Requests statistic processing result.
No
Yes
421 (01A5)
Memory switch set 1
(3000-series)
Sets memory switches.
Yes
No
422 (01A6)
Memory switch set 2
(3000-series)
Sets memory switches.
Yes
No
423 (01A7)
Simple AVG times set
(3000-series)
Taking the simple average as the
averaging method, sets the averaging
times per measurement interval 4.
Yes
No
424 (01A8)
AVG move interval set
(3000-series)
Taking the average move as the aver-
aging method, sets the measure-
ment interval number.
Yes
No
425 (01A9)
AVG move (H) times set
(3000-series)
Taking the average move and high-
speed data output as the averaging
method, sets the averaging times per
measurement interval 4.
Yes
No
426 (01AA)
AVG move (L) times set
(3000-series)
Taking the average move and low-
speed data output as the averaging
method, sets the averaging times per
measurement interval 4.
Yes
No
427 (01AB)
Automatic detection set
(3000-series)
Sets work automatic detection func-
tion.
Yes
No
428 (01AC) Automatic detection release
(3000-series)
Releases the settings of work auto-
matic detection function.
No
No
429 (01AD) Automatic detection list
request (3000-series)
Requests the settings of work auto-
matic detection function.
No
Yes
430 (01AE)
3Z4L initialize (3000-series)
Clears the 3Z4L, sets the mm unit,
sets the memory unit, does not pro-
cesses statistics, and clears all statis-
tic memory.
Yes
No
431 (01AF)
Measurement condition set
(4000-series)
Sets measurement conditions.
Yes
No
432 (01B0)
Measurement condition
release (4000-series)
Releases measurement conditions
that have been set.
Yes
No
433 (01B1)
Measurement condition list
request (4000-series)
Requests the measurement condi-
tions that have been set and other
settings.
No
Yes
434 (01B2)
Single run measurement start
(4000-series)
When the sample measurement con-
dition is from 1 to 999, performs a sin-
gle run measurement and requests
the measurement results.
No
Yes
435 (01B3)
Deflection measurement start
(4000-series)
Starts a deflection measurement.
No
No
436 (01B4)
Continuous measurement start
(scan) (4000-series)
Starts a continuous measurement.
The scan notification method is used
for receive data.
No
Yes
Sequence
No.
Communications sequence
name
Function
Ladder interface
Notes
Send word
allocation
Receive
word allo-
cation
Содержание CJ1W-SCU41
Страница 2: ...6 60 6 6HULHV 6HULDO RPPXQLFDWLRQV RDUGV DQG 6HULDO RPPXQLFDWLRQV 8QLWV 2SHUDWLRQ 0DQXDO 5HYLVHG 0D ...
Страница 3: ...KX ...
Страница 5: ...XK ...
Страница 9: ......
Страница 19: ......
Страница 119: ......
Страница 177: ......
Страница 187: ......
Страница 221: ......
Страница 259: ......
Страница 317: ......
Страница 333: ......
Страница 373: ......
Страница 395: ......
Страница 407: ......
Страница 443: ......
Страница 463: ......
Страница 501: ......
Страница 509: ......
Страница 513: ......
Страница 525: ......
Страница 526: ... XWKRUL HG LVWULEXWRU Cat No W336 E1 3 Note Specifications subject to change without notice Printed in Japan 0501 M ...