Debug mode
Section 4-4
49
If the flag ’Extended Diag’ is set, the slave has additional diagnostic
information, and the button ’Ext Diagnostic’ will be available. Extended
diagnostics will be displayed in a separate window.
4-4-3
Extended diagnostics
The displayed extended diagnostic texts are dependent on the information
provided in the device’s GSD file. SyCon translates the diagnostic message
as received from the slave in hexadecimal format (bottom window) into the
texts as specified in the GSD file. Different language versions of the GSD file
may be available from the manufacturer.
If multiple messages are available, they can be selected for display using the
scroll bar on the right.
The meaning of the displayed messages is slave dependent, and should be
described in the slave’s documentation.