5 To perform shutdown processing of the devices when a power failure occurs
5-1 The outline on the UPS monitoring software
Additional Information
Explanation of software functions
Function name
Description
1. Auto shutdown
The computer can be shut down automatically when a problem occurs
with the power supply.
2. UPS monitoring (operating status) The operating status of the UPS can be monitored (in Commercial Power
Mode/Battery Mode).
3. UPS monitoring (data)
Monitoring can be performed for input voltage value, connection capacity,
battery capacity, etc.
4. Pop-up notification
When a problem such as a power failure occurs, a pop-up window that
shows the details of the problem can be displayed depends on OS.
5. Shutdown when OS is inactive
Shutdown can be performed when the computer is in an inactive state.
The operating status is retained at shutdown in inactive state, so
operation details are not lost.
6. Schedule operation
Schedule settings can be made for UPS stop/start.
7. UPS setting change
UPS settings (beep ON/OFF, etc.) can be changed. (Items that can be
set vary according to the UPS.)
8. External command execution
By executing commands at shutdown, items such as application
programs can be launched.
9. Event log save
Information of events that occur on the UPS (power supply problems,
setting changes, occurrences of failure, etc.) are saved as a log.
10. Data log save
Data of input/output voltage value, connection capacity, etc. is
periodically saved as a log (the save frequency can be set).
11. Coordinated shutdown
When a problem occurs with the power supply, multiple computers
connected to the UPS can coordinate to perform auto shutdown.
12. Output receptacle control
The UPS output receptacles can be individually set to ON/OFF.
13. Redundant power supply support Two or more UPS can be connected to computers equipped with
redundant power supply. Shutdown is not performed when a power
supply problem affects only one of the units. Shutdown is performed only
when a power supply problem occurs with both UPS, so the system's
operating rate is improved.
14. Remote UPS management
The UPS can be managed remotely from a computer on the network.
15. Mail send
When a problem such as a power failure occurs, a notification email
describing the problem can be sent to the system administrator.
16. SNMP management
UPS management information can be sent to the SNMP manager.
17. Telnet connection
Settings such as shutdown parameters can be made via the Telnet
connection.
18. SYSLOG support
UPS management information can be recorded in SYSLOG.
BA75T/BA100T/BA100R
78
Содержание BA100R
Страница 23: ...2 Installation and connection 2 1 Installation Incorrect Positions BA75T BA100T BA100R 22...
Страница 87: ...8 Note of Chinese 8 Note of Chinese UPS UPS 1 UPS FA OA Windows BA75T BA100T BA100R 86...
Страница 88: ...8 Note of Chinese 2 FA OA A VCCI A BA75T BA100T 12 5 BA100R 13 BA75T BA100T BA100R 87 8...
Страница 89: ...8 Note of Chinese AC AC100V 110V 115V 120V 50 60Hz AC UPS 10 90 0 C 40 C 25 85 BA75T BA100T BA100R 88...
Страница 90: ...8 Note of Chinese 5cm AC 25 5 30 4 AC AC AC AC BA75T BA100T BA100R 89 8...
Страница 91: ...8 Note of Chinese ON OFF AC INPUT PROTECTION 1mA AC UPS AC UPS BA75T BA100T BA100R 90...
Страница 92: ...8 Note of Chinese BA75T BA100T BA100R 91 8...
Страница 93: ...8 Note of Chinese AC UPS 25 25 6 40 2 AC AC DC250V BA75T BA100T BA100R 92...
Страница 94: ...8 Note of Chinese UPS 100V http www fa omron com cn AC AC 50 60Hz 3 3 3 Pb BA75T BA100T BA100R 93 8...
Страница 97: ...9 References 9 2 Dimensions 9 2 Dimensions Unit mm Tolerance 2mm BA75T BA100T BA100R BA75T BA100T BA100R 96...
Страница 98: ...9 References 9 2 Dimensions Unit mm Tolerance 1mm Upright stand for BA75T 100T BAP100T BA75T BA100T BA100R 97 9...
Страница 99: ...9 References 9 2 Dimensions Upright stand for BA100R BAP100R BA75T BA100T BA100R 98...
Страница 100: ...9 References 9 2 Dimensions Rubber feet BA75T BA100T BA100R 99 9...
Страница 101: ...9 References 9 2 Dimensions Using Ear brackets BAP100RS BA75T BA100T BA100R 100...
Страница 103: ...9 References 9 4 China RoHS Information 9 4 China RoHS Information BA75T BA100T BA100R 102...