3-4
3-1 Parameter Description of Each Function
3
Funct
ions
BCD Dividing Input
The set data can be changed in two data inputs for MSB and LSB.
In addition, changing the type code enables to change the settings of frequency, torque limit, accel-
eration/deceleration time, and position (For the type code, refer to "3-2 Type Code"(Page 3-5)).
The set resolution can be selected using the rotary switch (CODE).
The data bit configuration of the BCD dividing input is shown below.
Setting Example
When setting the acceleration time to 60.0 sec with a resolution of 0.1 sec (Rotary switch setting
(CODE): 1,4,7,A)
1. Convert the value of 60 multiplied by 10 into the BCD binary value. Next, input the
MSB 2 digits in terminals D7 to D0, and input the acceleration time MSB code in ter-
minals D15 to D8.
60
×
10 times = 600
→
0000011000000000 (binary)
2. When the data is entered, turn the strobe signal ON.
3. Turn the strobe signal OFF.
4. Input the rest of LSB 2 digits in terminals D7 to D0, and input the acceleration time
setting LSB code in terminals D15 to D8.
5. When the data is entered, turn the strobe signal ON.
6. Turn the strobe signal OFF.
Precautions
For details on signal input timing, refer to "3-3 Data Input Timing"(Page 3-6).
DIP switch TYPE setting
1
2
ON: BCD
ON: DIV
D11 D10
D 9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D15 D14 D13 D12
(MSB)
(LSB)
MSB or LSB type codes
MSB 2-digit or LSB 2-digit set data
0
1
0
0
0
0
0
0
0
1
1
0
0
0
0
0
Acceleration time setting MSB codes
MSB 2-digit set data
D11 D10
D 9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D15 D14 D13 D12
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
Acceleration time setting LSB codes
LSB 2-digit set data
D11 D10
D 9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D15 D14 D13 D12