2-7 Inverter Settings
2
Design
2-7 Inverter Settings
The Inverter (3G3RX) parameters related to the operation of the 3G3AX-DI Board are shown be-
low.
For operation, refer to “Chapter 3 Operation” and ”Chapter 4 Functions” of the Inverter 3G3RX Us-
er’s Manual, and make appropriate settings.
Note 1: To set the frequency, set the frequency reference selection (A001) to “Option” (04 or 05).
Note 2: To set the acceleration/deceleration time, set the acceleration/deceleration time input type
(P031) to “Option”.
Note 3: To set the torque limit, set the torque limit selection (b040) to “Option”.
Note 4: To set the orientation stop position, set the orientation stop position input type (P032) to
“Option”.
Parameter
No.
Function name
Data range
Default set-
ting
(3G3RX)
Changes
during
operation
Unit
A001
Frequency refer-
ence selection
00: Digital Operator (FREQ adjuster)
(Enabled when 3G3AX-OP01
is connected.)
01: Terminal
02: Digital Operator (F001)
03: ModBus communication
04: Option 1
05: Option 2
06: Pulse train frequency
07: Not used
10: Frequency operation result
02
×
−
b040
Torque limit
selection
00: Four-quadrant separate setting
01: Terminal switch
02: Analog input
03: Option 1
04: Option 2
00
×
−
P031
Acceleration/De-
celeration time
input type
00: Digital Operator
01: Option 1
02: Option 2
00
×
−
P032
Orientation stop
position input
type
00: Digital Operator
01: Option 1
02: Option 2
00
×
−