3-6
3-3 Data Input Timing
3
Funct
ions
3-3 Data Input Timing
Batch Input Mode Timing
Retrieve the data at the strobe signal ON level.
Set the ON/OFF time for the strobe signal to 20 ms or more. If the data indefinite period exceeds 5 ms,
turn the strobe signal OFF according to the following batch data input timing chart.
Precautions
Note that wrong data could be retrieved if the data input timing is not based on the above chart.
Data indefinite period
5 ms or less
Data indefinite period
5 ms or less
Data indefinite period
5 ms or less
Data definite
period
20 ms or less
Data definite
period
20 ms or less
Data definite
period
20 ms or less
Data definite
period
20 ms or less
Dn
(n=0-15)
STRB
SEQ
(Sequence error output)
0 ms
or more
20 ms
or more
0 ms
or more
ON
OFF
ON
20 ms
or more
20 ms
or more
OFF
ON
OFF
20 ms
or more
20 ms
or more
OFF
Normal data
Fault data
Normal data
Normal data