AC Servomotors/Servo Drives 1S-series Instruction Manual
Peripheral Equipment Connection Examples
R88D-1SAN02H-ECT/-1SAN04H-ECT/-1SAN08H-ECT/-1SAN10H-ECT
Note: For single-phase inputs, connect between any two phases out of the following: L1, L2, and L3.
• Provide single-point grounding of the ground plate for unit frame grounding as shown in the
above diagram.
• Use a ground wire with a minimum thickness of 2.5 mm
2
and arrange the wiring so that the
protective earth wire is as short as possible.
• Install a surge absorber and noise filter near the main circuit connector of Servo Drive.
Separate I/O wires from each other for the wiring.