Button Description
Replaced
Click this button when a label with detected errors is replaced with a known good
label. This action marks the label as !RP (replaced) in the error log file and is
removed from the errors list. The button is active when the job is in run mode.
Only operators granted the
Allow Accept / Replace Errors
permission are allowed
to use this feature. See the
Permissions
section, within the
Operators
section, for
more information on permissions.
Hide Barcode
Stats
Click this button to hide the barcode parameters on the screen and enlarge the
barcode image.
After clicking this button, the button name changes to “Show Barcode Stats.” Click
this button for the barcode parameters to appear on the screen.
The settings for this button are controlled in the LVS7500.ini file > [System] section >
ShowRuntimeGradeStats setting.
•
ShowRuntimeGradeStats=0 (default)
– Disables the “Hide Barcode Stats”
button.
•
ShowRuntimeGradeStats=1
– Enables the “Hide Barcode Stats” button.
Close
Click the “Close” button to close the error display window and return to the “Running
the Job” screen.