HideAlarmMatrix displays or hides the “Step 6: Alarm Matrix” screen.
o
HideAlarmMatrix=0 (default) displays the Alarm Matrix screen.
o
HideAlarmMatrix=1 hides the Alarm Matrix screen. The software will skip “Step 6: Alarm Matrix” and the
user will never see this screen.
•
IgnoreHealthCheck is for
Omron Microscan
technician use only.
•
Inactivity Timeout automatically logs out any user if the system is left idle for the defined amount of time.
This value is defined in minutes.
•
LaneDivision splits a job into its separate lanes for LVS-RIMS systems in case they were slit on the press; it
prints a barcode per lane as well. Note that LaneDivision does not function in conjunction with the Turret
signal.
o
LaneDivision=0 means the feature is disabled.
o
LaneDivision=1 means the feature is optional -- prompt the operator whether or not to split lanes.
o
LaneDivision=2 means the feature is required -- do not prompt the operator.
o
LaneDivision=3 is for non-RIMS applications where "channel" information is uploaded via Tcp/Ip.
•
LvsContactSensor is for
Omron Microscan
technician use only.
•
LvsContactSizeY is for
Omron Microscan
technician use only.
•
MakeReady is used when the operator needs to ignore a specified string in a sector at the beginning of a
job. For instance, type in the word VOID and the software will ignore that word at the beginning of the job
only.
•
MaxErrPerSec prevents the software from failing when inundated with errors; it will not create more than 30
thumbnails of errors per second. After 30 errors, no more thumbnails will be collected until the next second.
•
MaxThumbnails is the amount of thumbnail images that will be stored.
•
MaxTriggerGap causes an error if photo-eye triggers have stopped after a certain distance. Do not alter this
setting unless instructed by
an Omron
Microscan
technician.
•
MonthsBeforePasswordChange prompts users for passwords to be changed after the number of months
entered.
•
NumPacketThreads is the number of threads; it is set by how many processing CORES are available per
PC.
•
OneBigBlemishSector make the autosetup feature not separate label lanes.
•
PDF417UEC stops PDF from using ISO. PDF417UEC =1 only uses UEC as grade.
•
Pharmacode indicates whether pharmacode is included in the automatic 1D barcode reading/discrimination:
o
Pharmacode=0 means pharmacode
is not
included in the automatic 1D barcode
reading/discrimination.
o
Pharmacode=1 indicates pharmacode
is
included in the automatic 1D barcode reading/discrimination.
•
PhotoeyeSignalDelay is utilized to externally synchronize a line scan, or trigger an area scan LVS-7500.
•
RelearnAuthorization – When enabled, prevents the operator from using the “Ctrl+L” shortcut key or
“Update Spot Ignore” feature unless the operator has administrative rights. If the operator does not have
administrative rights, a pop-up message will appear requiring the operator to enter an authorized user name
and password.
o
RelearnAuthorization=0 indicates a pop-up message will not appear. Any user can press Ctrl+L and any
user with “Allow Accept/Replace Errors” privileges can press “Update Spot Ignore”
o
RelearnAuthorization=1 indicates a pop-up message will appear when an operator attempts to use
Ctrl
+L or “Update Spot Ignore.” The operator must enter an administrator user name and password to
continue.
•
ReportUnusedCodes - If enabled, a button entitled “Report unused codes” appears. This is used to
generate