ResyncMatchFileOnMismatch - If enabled, whenever a mismatch error occurs, the system will assume it is
possibly not in the right location in the match file and try to find where it is again. This allows the system to
recover instead of generating non-stop mismatch errors after an inserted or deleted label.
•
ShowBlemishMotion should only be changed by a
n
Omron Microscan
technician.
•
ShowElapsedTime is not user configurable and should not be altered unless requested by a
n
Omron
Microscan
representative.
•
ShowReportLabel enables or disables the “Report label” field on the “Step 5: Setup Matching” screen. The
Report label field acts as a unique user-defined identifier of a sector.
o
ShowReportLabel=0 (default) – disables the “Report label” field on the “Step 5: Setup Matching” screen.
o
ShowReportLabel=1 – enables the “Report label” field on the “Step 5: Setup Matching” screen.
•
ShowRuntimeGradeStats enables or disables the “Hide Barcode Stats” button on the Error Display screen.
o
ShowRuntimeGradeStats=0 (default) – Disables the “Hide Barcode Stats” button.
o
ShowRuntimeGradeStats=1 – Enables the “Hide Barcode Stats” button.
•
ShowSnapshotButton=1 enables the “Snapshot” button to appear on the “Operate: Running the Job” screen
that enables a snapshot to be taken of the next repeat. This setting should not be altered unless instructed
by a
n
Omron Microscan
representative.
o
ShowSnapshotButton=0 disables the “Snapshot” button.
•
ShowStatusAlert enables the Bypass and MakeReady screens to flash colors (Bypass screen flashes
yellow/white; MakeReady screen flashes red/white), and enable the scrolling message (“Bypass” or
“MakeReady”) to appear across the top, left corner of the screen.
o
ShowStatusAlert=0 disables the flashing screens and scrolling text.
o
ShowStatusAlert=1 enables the flashing screens and scrolling text.
•
SkipAutoSetupShrink indicates whether rectangular borders around labels or space in-between labels are
detected when using Automatic Setup.
o
SkipAutoSetupShrink=0 (default). When drawing a sector around a label, the software automatically
detects rectangular borders around labels and space in-between labels.
o
SkipAutoSetupShrink=1 - When drawing a sector around a label, the software does not detect
rectangular borders around labels or space in-between labels. Sectors drawn become expanded to fill a
horizontal and vertical repeat. There are no gaps between labels.
•
SpotVoidCheck will error any spot anywhere within a barcode. Do not use unless instructed by a
n
Omron
Microscan
technician.
•
StripParentheses takes parentheses off decoded data strings from symbologies such as GS1 databar or
Datamatrix.
•
Strobe allows the system to be used in viewing mode like a strobe light. There must be a consistent sync
mark on the web to use this feature.
o
Strobe=0 allows the software to be used in its Normal mode.
o
Strobe=1 allows the software to be used in Strobe Mode.
o
Strobe=2 allows the software to be used in an Advanced strobe mode. Only use this setting if advised
by a
n
Omron Microscan
technician.
•
TiltedRead attempts to read a short in height barcode by applying a slight rotation.
•
TriggerStopMotionOnLearnBlemish tells the software to send a stop motion signal when a Blemish sector
has been defined. This helps to stop the Rewinder to visually inspect label(s) that are used as a golden
image.
o
TriggerStopMotionOnLearnBlemish=0 – Feature is off.
o
TriggerStopMotionOnLearnBlemish=1 – Signal will be sent to stop Rewinder after Blemish sector is
defined or Golden Image is relearned.