LVS-7500 External System Operations Manual
LVS-7500 External System Operations Manual
Page 116 of 129
TiltedRead=0
TriggerStopMotionOnLearnBlemish=0
TurretSignalDelay=0
UseBypassSignal=0
UsePhotoeyeSignal=0
UseTurretSignal=0
TcpIp Parameters:
These parameters are used when the LVS-7500 is connecting to another system.
•
Mode indicates if the LVS-7500 is connecting to another system. Options include:
o
Enter
<Remote>
if the LVS-7500 is connecting with a remote computer, such as the LVS-HMI
Command Center or a non-LVS system.
o
Enter
<off>
if the LVS-7500 is not connecting to another system. Note that all remaining settings (such
as Host, Port1, Port2, etc.) do not apply if the LVS-7500 is not connecting to another system.
•
Host: Do not change this setting; leave as is.
•
Port1: Enter the port where the first external system will be listening for
Omron Microscan
data.
•
Port1Filter: Do not change this setting; leave as is.
•
Port2: Enter the port where the second external system will be listening for
Omron Microscan
data.
•
Port2Filter specifies the type of information received from the non-LVS system.
o
Enter <Blank> to receive all information.
o
Enter <7> to receive error only information.
[TcpIp]
Mode=off
Host=0.0.0.0
Port1=0
Port1Filter=
Port2=0
Port2Filter=