After correctly installing the top parts (1, 2, 3, 4, 6, 7, 8, 9) position the body of the disposer and tighten the connection
ring nut, rotating it all the way until reaching the mechanical travel limit of the LOCK position indicated in the figure:
Position the body of the food waste disposer so that the electrical rearm device is facing
outward and always easily reachable.
Every intervention on the electric parts must be carried out by a qualified professional in accordance with applicable
rules and regulations on injury prevention.
The user must prepare:
A correctly proportioned electric supply line, equipped with an isolating device complete with power surge
protection (ld = 0.03 A) and indirect contacts.
A line for the grounding connection.
Characteristics of the electric energy source:
Voltage: 220 – 240 V ± 10% L+N+T
frequency: 50 – 60 Hz
Максимальная мощность: 1,5 кВт
ELECTRIC CONNECTION
ATTENTION
USE OF THE FOOD WASTE DISPOSER IS PROHIBITED
To avoid hazards in cases where the cable or power plug are malfunctioned, defected or have anomalies the damaged
power cable must be replaced by the manufacturer or qualified personnel.
SAFETY
SYSTEM
LOCK
SWITCH
For installation of the food waste disposer START - STOP air switch follow the connection diagram shown in the figure:
BUTTON SWITCH INSTALLATION
Every intervention must be carried out by a qualified professional in accordance with the applicable rules and
regulations on injury prevention.
The user must prepare a proportioned water supply line
Characteristics of the water supply source:
Pressure: 1 - 1,5 Bar (100 -150 kpa)
Capacity : 8 - 20 L/min
WATER AND DRAINAGE CONNECTION
Before connecting the sink overflow drain piping, using a screwdriver and a hammer, remove the diaphragm
on the drain elbow.
OVERFLOW CONNECTION
Air switch
Gasket
Connection surface
(sink edge/surface)
Fixing ring nut
Pipe
Pipe fitting
1.
2.
3.
4.
5.
6.
Removal of the diaphragm
Example of sink overflow drain connection
1
2
3
4
5
6
35 mm
(1,38’’)
MAXa
30 mm
(1, 18’’)
Содержание Nagare 1000
Страница 1: ...RU EN Manual JP Nagare 1000 750 500...
Страница 4: ...5 6 C...
Страница 7: ...11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 1 2 3 4 1 2 3 4...
Страница 8: ...13 14 1 2 3 4 5 6 7 8 WEEE V 1 2 3 1 2 3 4 5 6 7 b c...
Страница 16: ...29 30...
Страница 19: ...35 36 20 30 6 8 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 30 1 1 1 5 1 2 3 4 1 2 3 4...
Страница 20: ...37 38 1 2 3 4 5 6 7 8 WEEE 5 OMOIKIRI 230 1 2 3 1 2 3 4 5 6 7 5 8...