Chapter 3 - Getting Connected
Manual Rev. 1.02
Page 17
Data-Link DL100 1.00 Unit Serial # : 510002168
Unit ID : Data-Link
Date : THU 01/06/00 % Full alarm : OFF
Time : 13:40:10 No Data Alarm 1: OFF
Memory : 256K No Data Alarm 2: OFF
% Full : 01% Release mode : LINE
Modem : NONE Duplex : FULL
Network : Yes Password : ON
IP Add : 192.168.105.12 Compress : OFF
MAC Add : 00:11:C3:A1:2F:0F
-----------------------------------------------------------
Port 1 Port 2 Port 3 Port 4
Baud Rate 19200 19200 19200 19200
Parity, etc. 8N1 8N1 8N1 8N1
File Records 00000000 00000005 00000000 00000000
File Bytes 00000000 00000026 00000000 00000000
File % Full 00% 00% 00% 00%
ASCII/Binary ASCII ASCII ASCII ASCII
Handshake XON/XOFF XON/XOFF XON/XOFF XON/XOFF
File Wrap OFF OFF OFF OFF
Alarm Filter NONE NONE NONE NONE
The status screen in the DL100 is dynamically created according to the configuration of each
particular unit. Because of this, the above example may not be identical to another.
Unit ID
is the identifier assigned to each DL100 by the end user.
Date
and
Time
are displayed for user informational purposes.
Memory
indicates the amount of data-ready memory installed on the DL100.
% Full
indicates the percent of the memory installed that is currently occupied by serial port data
and alarm records.
Modem
and
Network
both indicate whether or not that hardware is installed in the DL100. This
status is marked by a YES or NONE.
If a network interface is installed, the
IP Add
and
MAC Add
display the appropriate address
values. The MAC address is displayed for informational purposes and cannot be changed.
Unit Serial #
is the factory-assigned, unique serial number for each individual unit.
% Full Alarm / No Data
Alarm
indicates the current ON/OFF status of the 80% full alarm and
no data alarms 1 and 2, respectively.
Release Mode
indicates the current command processor data release method. This can be line,
CBB, or Xmodem.
Duplex
controls the echo settings for the command processor. Full duplex causes the DL100 to
echo all characters sent to the remote device. Half duplex turns off character echo.
Содержание Data-Link DL100
Страница 4: ...Omnitronix DL100 User s Manual Page 2 ...
Страница 16: ...Omnitronix DL100 User s Manual Page 14 ...
Страница 38: ...Omnitronix DL100 User s Manual Page 36 ...
Страница 42: ...Omnitronix DL100 User s Manual Page 40 ...
Страница 52: ...Omnitronix DL100 User s Manual Page 50 ...
Страница 56: ...Omnitronix DL100 User s Manual Page 54 ...