Electrical Connection (required)
•
The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and
must meet all local codes.
•
Make sure the household breaker is shut off prior to working on any electrical lines.
•
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
•
The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps).
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation.