Additional Instructions for Firebeam products

 

 

**Installation must be carried out by a qualified and competent person** 

 

 

 

Electrical connection 

The fire can be connected directly to a 13 amp fused switched spur or plugged into a mains 

socket which can be sited on the

 

right hand side of the fire. It is imperative that the power supply 

is capable of handling a load

 

of 2000 watts (2kw). This appliance must be earthed. Do not use 

an extension lead. 

 
The Beam LED lighting will

 

require an additional mains supply. This can be wired directly into the 

mains supply with a 3 amp fused switched spur or plugged into a mains socket. 
 

Ensure that both of the plug socket-outlet connections for this appliance are accessible for easy 
electrical isolation in the event of servicing and replacing components etc. 
 

Always ensure that all electrical work complies with the relevant Building Regulations

 

and the Electrical Code of Practice. All electrical work should be carried out by a

 

qualified electrician. 
 

 
 

Choosing a suitable location 

This electric fire is designed to be fitted within an existing brick / masonry chimney breast or 

within a false studded chimney breast. The base of the fire opening must be solid, level and firmly 
fixed to safely support the weight of the fire. 
 
If the product is installed into an existing brick / masonry chimney breast it must be dry with the 

chimney capped off using a suitable chimney cap.

 

The appliance must be kept away from any 

source of damp or moist conditions. 
 

Important Notice: To reduce heat losses and to prevent any chimney up draught

 

affecting the operation of your fire we recommend that the chimney is blocked off. 
 

The chimney breast, wall or fireplace must be of sound construction and all fixings used must

 

be suitable for the type of wall. If there is any doubt regarding the suitability of the installation

 

site please contact your supplier. 

 

From the front of the fire ensure that there is a minimum clearance of 50mm between any

 

non-combustible materials. For combustible material clearances please consult with the

 

manufacturer. 

 
This appliance MUST NOT be located immediately below an electrical socket-outlet. 
 

 

 

Содержание Firebeam Ultiflame VR 600

Страница 1: ...alified electrician Choosing a suitable location This electric fire is designed to be fitted within an existing brick masonry chimney breast or within a false studded chimney breast The base of the fire opening must be solid level and firmly fixed to safely support the weight of the fire If the product is installed into an existing brick masonry chimney breast it must be dry with the chimney cappe...

Страница 2: ...h this can be drilled on the left or right side dependent on the position of the power supply This should be in line with the bottom of the fire opening and 50mm from the edge The fire can be fixed into the chimney breast using the 4 fixing holes as shown below The chimney wall can now be finished with plasterboard or an alternative facing material which terminates at the facing trim Ultiflame VR ...

Страница 3: ...Fitting the FireBeam The firebeam is hung on the wall by locating onto 2 screws Ensure that suitable screws and wall fixings are used See below diagrams for drilling positions Ultiflame VR 600 Ultiflame VR 800 ...

Страница 4: ...m to drop into position to locate fully within the keyhole slot brackets Finally fit the decorative glass into the glass holders as shown and clamp into place by carefully adjusting the screws on the back of the glass holders 1167 1033991 Issue 1 BFM Europe Ltd Gordon Banks Drive Trentham Lakes Stoke on Trent ST4 4TJ Technical Queries 01782 339039 Service Fault Enquiries 01782 339008 ...

Отзывы: