The fire opening is to be a minimum of 225mm from the floor. 
 

       
        Table of fire opening sizes 

 
 

 
 
 

 
 
 

 
 
An additional clearance hole is required to feed the 
mains cable through for the power supply to the 

Firebeam LED lights. 
 
Drill a suitable sized hole to feed the mains cable 

through (this can be drilled on the left or right side 
dependent on the position of the power supply). 
This should be in line with the bottom of the fire 

opening and 50mm from the edge. 
 
The fire can be fixed into the chimney breast using the 4 fixing holes as shown below. 

 

 

The chimney wall can now be finished with plasterboard or an alternative facing material which 
terminates at the facing trim.  

 

 

 

 

 

 

 

 

 

 

Ultiflame VR 600  Ultiflame VR 800 

Height 

650mm 

605mm 

Width 

610mm 

890mm 

Depth 

185mm 

185mm 

Содержание Firebeam Ultiflame VR 600

Страница 1: ...alified electrician Choosing a suitable location This electric fire is designed to be fitted within an existing brick masonry chimney breast or within a false studded chimney breast The base of the fire opening must be solid level and firmly fixed to safely support the weight of the fire If the product is installed into an existing brick masonry chimney breast it must be dry with the chimney cappe...

Страница 2: ...h this can be drilled on the left or right side dependent on the position of the power supply This should be in line with the bottom of the fire opening and 50mm from the edge The fire can be fixed into the chimney breast using the 4 fixing holes as shown below The chimney wall can now be finished with plasterboard or an alternative facing material which terminates at the facing trim Ultiflame VR ...

Страница 3: ...Fitting the FireBeam The firebeam is hung on the wall by locating onto 2 screws Ensure that suitable screws and wall fixings are used See below diagrams for drilling positions Ultiflame VR 600 Ultiflame VR 800 ...

Страница 4: ...m to drop into position to locate fully within the keyhole slot brackets Finally fit the decorative glass into the glass holders as shown and clamp into place by carefully adjusting the screws on the back of the glass holders 1167 1033991 Issue 1 BFM Europe Ltd Gordon Banks Drive Trentham Lakes Stoke on Trent ST4 4TJ Technical Queries 01782 339039 Service Fault Enquiries 01782 339008 ...

Отзывы: