3-11
1. Channel Type Button
The channel type selects between physical and math channel input types.
Current inputs are physical input channels.
2. Input Type Settings
For current inputs there no sensor types or sub types available. Only 1
channel is required per current input, but a 50 Ω shunt resistor must be
installed across the input terminal. A channel number, color and name must
be assigned for each channel.
3. Channel Map
The channel map provides a quick view of which channels have already
been configured (blue) and the currently selected channel (orange).
Standalone Operation
3
Current Inputs
For current inputs the Input Type screen appears as shown below. A 50 Ω shunt
resistor is required across the input terminals for current inputs.
Figure 3-13 Input Type – Current
2
1
3
Содержание OM-DAQXL-1 Series
Страница 75: ...4 1 NOTES 4...