Introduction 

(continued)

 

Step One 

  

 

 

About  this  Manual:

  PLEASE  READ  THE  ENTIRE  MANUAL  PRIOR  TO  INSTALLING  OR  USING  THIS 

PRODUCT.    This  manual  includes  information  on  the  LVU700  series  Ultrasonic  Level  Transmitter  from 
OMEGA ENGINEERING.  Please refer to the part number located on the switch label to verify the exact model 
configuration, which you have purchased.   

 

User’s Responsibility for Safety:

  OMEGA ENGINEERING manufactures a broad range of level sensing 

technologies.  While each of these sensors is designed to operate in a wide variety of applications, it is the 
user’s responsibility to select a sensor model that is appropriate for the application, install it properly, perform 
tests  of  the  installed  system,  and  maintain  all  components.    The  failure  to  do  so  could  result  in  property 
damage or serious injury. 

 

Proper Installation and Handling:

  Only professional staff should install and/or repair this product.  

Never

 

over tighten the sensor within the fitting.  Always check for leaks prior to system start-up.  

 

Wiring and Electrical: 

 A supply voltage of 14 to 28 VDC is used to power the LVU700 series.  Electrical 

wiring of the transmitter should be performed in accordance with all applicable national, state, and local codes.  

 

Material  Compatibility:

    The  enclosure  is  made  of  Polypropylene  (PP).    The  transducer  is  made  of 

Polyvinylidene Fluoride (PVDF).  Make sure that the model, which you have selected, is chemically compatible 
with the application media.   

 

Enclosure: 

  While  the  sensor  housing  is  liquid-resistant  the  LVU700  series  is  not  designed  to  be 

operational when  immersed.    It  should  be  mounted  in  such  a  way  that  the  enclosure  and  transducer  do not 
come into contact with the application media under normal operational conditions.   

 

Handling Static-Sensitive Circuits/Devices:  

When handling the transmitter, the technician should follow 

these  guidelines  to  reduce  any  possible  electrostatic  charge  build-up  on  the  technician’s  body  and  the 
electronic part. 

1.  Always touch a known  good ground source before handling the part.   This should be repeated while 

handling the part and more frequently after sitting down from a standing position, sliding across the seat 
or walking a distance. 

2.  Avoid touching electrical terminals of the part unless making connections. 

3.  DO NOT open the unit cover until it is time to calibrate. 

 

Make a Fail-Safe System:

  Design a fail-safe system that accommodates the possibility of switch and/or 

power  failure.    OMEGA  ENGINEERING  recommends  the  use  of  redundant  backup  systems  and  alarms  in 
addition to the primary system. 

Flammable, Explosive or Hazardous Applications:

  

LVU700 series should not be used within classified hazardous environments. 

 

Warning:

 Always use the FKM gasket when installing “G” threaded versions of LVU700 series. 

 

Warning:

 Make sure that all electrical wiring of the switch is in accordance with applicable codes.

 

Содержание LVU-700

Страница 1: ...1...

Страница 2: ...2...

Страница 3: ...on 3 Specifications 5 Dimensions 6 Reflective Technology 7 About this manual 8 Getting Started 9 Setup Overview 9 Components 1 LVCN414 SW software vs Display Configuration 11 Understanding Sensor Heig...

Страница 4: ...Displays Controllers PLCs 36 LVCN414 SW software Appendix 37 Sensor Configuration 37 38 Volumetric Configuration 39 41 Tank Level Confirmation 42 Write to Unit 43 Display Appendix 44 Air Gap vs Liquid...

Страница 5: ...VU706 2 NPT or 2 G LVU712 3 NPT or 3 G Gasket FKM G thread only Electrical Connections Power Return 2 pin removable terminal block Display Connect 4 pin removable terminal pins Non Display version Blo...

Страница 6: ...6 Introduction continued Step One DIMENSIONS Dimensions for LVU706 Series Dimensions for LVU712 Series...

Страница 7: ...their measurement reliability At the core of Reflective Technology is a simple fact Unlike flat horizontal surfaces significant water droplets cannot adhere to smooth vertical surfaces By orienting t...

Страница 8: ...idene Fluoride PVDF Make sure that the model which you have selected is chemically compatible with the application media Enclosure While the sensor housing is liquid resistant the LVU700 series is not...

Страница 9: ...ing the LVCN414 SW software configuration software 4 Configure Sensor with Push Button Section Four a Section 4 contains information on using the Push Button Display to configure the sensor 5 Install...

Страница 10: ...peration of LVU700 series P N Max Range Dead Band Thread Fob Output Configuration LVU706 B 19 7 6m 8 20cm 2 NPT Not Included 4 20 mA Display with Push Button or LVCN414 SW software LVU706 Included LVU...

Страница 11: ...es can be configured before installation or after installation The transmitter features non volatile memory so any settings configured before installation will not be lost when the sensor is powered d...

Страница 12: ...e tank and any risers fittings structures or extensions associated with the tank or the installation see examples below The reference point for definition of the Sensor Height is always the bottom of...

Страница 13: ...of the tank Note The ratio of height to diameter of the riser must be no greater than 2 1 Any higher and the sensor will target the inside wall of the riser Example 2 Dome Top Tanks Tank C has a tall...

Страница 14: ...e installation of the sensor Be sure to understand the geometry directly underneath the sensor Cone or rounded bottom tanks will provide off angled surfaces that can reflect the ultrasonic sound energ...

Страница 15: ...s i e inches feet gallons meters liters etc Tank A Tank B Tank C In the Tank A example the Sensor Height sets the 4mA to the bottom of the tank Fill Height sets the 20mA to the top of the straight sid...

Страница 16: ...nt 3 Sensor Configuration a Configures Loop Fail Safe Output at Empty Startup Condition for the sensor 4 Dimensional Entry a Distance Mode default i Basic information for operation Sensor Height Fill...

Страница 17: ...W software prior to plugging in the USB Fob LVU500 USB Please go to http www omega com ftp Click on Flow Level pH Environmental and Pressure Section and press on Products Select the LVCN414 folder Sel...

Страница 18: ...eries Use only the Red Black Green and White wires The maximum cable distance between the computer and LVU700 series is 15 This only applies for configuring the LVU700 series Once LVU700 series is con...

Страница 19: ...hand sensors installed in risers nozzles will result in a higher HEIGHT value The basic measurements Height and Fill H for configuration are described below 1 HEIGHT Sensor Height Distance from the b...

Страница 20: ...neer at 833 484 6072 STEP 3 SENSOR CONFIGURATION Configures the Loop Fail Safe Output at Empty and Startup Condition for the sensor Note When connecting the sensor to the LVCN414 SW software you must...

Страница 21: ...s refer to VOLUMETRIC CONFIGURATION on page 40 The two values Sensor Height and Fill Height below set the 4 20 mA current span for the sensor Both values will be set in the units shown under Height Un...

Страница 22: ...To adjust these settings click on Volumetric Modes STEP 6 WRITE TO UNIT This LVCN414 SW software operation uploads configuration into the sensor Other features in the section include providing a custo...

Страница 23: ...length including Feet Inches Centimeters or Meters 3 Set the Sensor Height HEIGHT a This is the empty setting 4mA for the tank 4 Set the Fill Height FILL H a This is the full setting 20mA for the tan...

Страница 24: ...sensors installed in risers nozzles will result in a higher HEIGHT value The basic measurements Height and Fill H for configuration are described below 1 HEIGHT Sensor Height Distance from the bottom...

Страница 25: ...U items will rotate through display 3 Use OK to choose a MENU item How to exit the TOP LEVEL MENU In TOP LEVEL MENU press OK when RUN appears STEP 2 SETTING THE UNITS OF MEASUREMENT UNITS 1 In the TOP...

Страница 26: ...bottom of the tank 4 To enter the value press and hold OK for 3 seconds and release SAVED will display 5 Select EXIT to return to TOP LEVEL MENU Note The HEIGHT setting also determines the 4 mA curren...

Страница 27: ...the bottom of the tank 4 To enter the value press and hold OK for 3 seconds and release SAVED will display 5 Select EXIT to return to TOP LEVEL MENU Note The Fill Height FILL H setting determines the...

Страница 28: ...utput or LOST setting can be set to output a current of 4mA 20mA 21mA 22mA or Hold last known value During fail safe the display will read LOST 1 In TOP LEVEL MENU mode select OUTPUT 2 Select SAFE 3 S...

Страница 29: ...side wall 4 Do not mount where obstacles will intrude on sensor s beam width a mount at least 3 from the side wall 5 Do not mount in a vacuum 6 Do not mount in the center of a dome top tank 7 In cone...

Страница 30: ...Adapter Socket x Thread LVU800 2B shown Tank Adapter LVU800 3B w 3 x2 Reducer Bushing LVU800 3N40 Tank Adapter Thread x Thread Do not use thread x thread 2 Riser Installations with tall narrow risers...

Страница 31: ...complete the installation 2 Flange w thread out of plane LVU800 2F 3 Flange LVU800 3F w Reducer Bushing LVU800 3N80 4 Side Mount Bracket For installations in open tanks and sumps use the LVM 30 serie...

Страница 32: ...pipe should remain submerged at all times to prevent foam from entering the pipe e Cut a 45 notch at the bottom of the pipe Drill a 1 4 pressure equalization hole in the dead band f The pumps should...

Страница 33: ...414 SW software and use the wiring diagram button to view the appropriate diagram Each configuration will have its own unique diagram The diagram shown above is only a sample and should not be used as...

Страница 34: ...ERAL NOTES FOR ELECTRICAL CONNECTIONS USAGE AND SAFETY Where personal safety or significant property damage can occur due to a spill the installation must have a redundant backup safety system Wiring...

Страница 35: ...his application To access the terminals gently remove the display from the housing When wiring is completed restore the display to the housing and replace the cover The LVU700 series can operate witho...

Страница 36: ...VU700 series to common display controllers and PLC s LVCN 51 Series Level Controller JWA mode Factory Setting LVCN 51 Series Level Controller JWB mode Generic Loop Powered Display Generic PLC Refer to...

Страница 37: ...d the sensor will output 20 mA during a fail safe condition Full The output will revert to the current value for a full condition When 4 mA at Bottom is selected the sensor will output 20 mA during a...

Страница 38: ...tput will revert to the selected current value for an empty condition o 4 mA at Bottom The sensor will output 4 mA while the sensor powers up o 20 mA at Bottom The sensor will output 20 mA while the s...

Страница 39: ...rtional to the volume of the tank not the height of the tank This means that the current output will track the volume of the tank in gallons or liters Depending on the shape of the tank the values may...

Страница 40: ...t Units as Distance or Volume After choosing the Sensor Output Units select the units of measurement in the pull down to the left Units of Measurement Distance Volume Inches Cm Feet Meters Gallons Lit...

Страница 41: ...tank to the top of the straight side wall Diameter Distance of the inside tank diameter Volume Tank Capacity Vertical Cylinder Example After entering the dimensions press the Capacity button to show t...

Страница 42: ...tank to the bottom of the sensor Fill Height Distance from the bottom of the tank to the operational full level of liquid 20mA This setting defines the location of full current output and is the top...

Страница 43: ...is a feature setting designed to help solve performance or operational issues for specific applications Changing these setting will alter the factory default performance or operation of your sensor I...

Страница 44: ...LIQUID mode or the amount of air in the tank AIR mode This function does not influence the current output just the display on the sensor 1 In TOP LEVEL MENU mode select DISPLAY 2 Select LIQUID or AIR...

Страница 45: ...hen use the REV MA setting to reverse the current output With REV MA set to NORM factory default 4mA will be at the bottom and 20 mA at the top of the tank With REV MA set to REV 20mA will be at the b...

Страница 46: ...he level reading the output current can be preset in order to avoid any false alarms during this window The options for start up are 4mA 12mA 20mA or 22mA 1 In TOP LEVEL MENU mode select OUTPUT 2 Sele...

Страница 47: ...t the following information a UNITS b DISPLY c REV MA d SAFE e HEIGHT f FILL H g START UP 4 Select EXIT to return to TOP LEVEL MENU DIAGNOSTIC DIAG PARAMETERS This mode runs diagnostic tests that conf...

Страница 48: ...LVU700 series enables the end user to reset the entire configuration back to the original factory settings 1 In TOP LEVEL MENU mode select VALUES 2 Select RESET 3 Select YES a To cancel the reset Sel...

Страница 49: ...connected to the computer Check that the LVU500 USB Fob is connected to the USB port Check that all four wires Red Black White and Green are securely attached to the Fob Check Device Manager and confi...

Страница 50: ...iquid in the tank Change the DISPLAY mode from AIR to LIQUID or vice versa to correct Transmitter indicates a current of 0 mA Check the wiring for an open circuit An open circuit is the most common is...

Страница 51: ...51...

Страница 52: ...52...

Отзывы: