31
➀
PV value display
PV
Displays the measured value, as well as
the failure information. When more than
one failure occurs simultaneously, the
failure information of the highest priority
alone will be displayed.
Display
Priority
Main unit failure
Heater disconnected
Control loop failure
High
Meaning
Low
➁
Set point value display
SV
Displays the set point value.
(During auto-tuning or manual operation,
the display of
or
and set point value alternate.)
➂
Control output-1 monitor lamp
Output 1(OUT1)
Lights when Output 1 is ON. (it does not
light for the current output type.)
➃
Control output 2 or remote operation monitor lamp
This lamp lights when Output 2 is ON or
during remote operation. (it does not
light for the single output type.)
Dual Control type
Output 2(OUT2)
Acts as the control output 2 monitor lamp.
Remote SV type
REM
Acts as the remote operation monitor lamp.
●
●
●
●