background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 

prior written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE  

contacting OMEGA:
1.   Purchase Order number under which the product 

was PURCHASED,

2.   Model and serial number of the product under 

warranty, and

3.  Repair instructions and/or specific problems  

  relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult OMEGA 

for current repair charges. Have the following 

information available BEFORE contacting OMEGA:
1.  Purchase Order number to cover the COST  

  of the repair,
2.  Model and serial number of the product, and
3.  Repair instructions and/or specific problems  

  relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED 

RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit. 

 

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

37 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month 

grace period to the normal 

three (3) year product warranty

 to cover handling and shipping time. 

This ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for  

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

Содержание CL1000 Series

Страница 1: ...nt Dry Block Probe Calibrator 230 VAC Model Only CAUTION This product is not intended for medical use or use on humans e mail info omega com For latest product manuals www omegamanual info Shop online...

Страница 2: ...RNING These products are not designed for use in and should not be used for human applications Servicing North America U S A Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 US...

Страница 3: ...Reset Switch 3 3 3 3 Rear Panel Connections 3 3 3 3 1 AC Power Input 3 3 3 3 2 Power Switch 3 3 3 4 Controller Parameters Settings 3 4 3 4 1 Changing Controller Parameter Settings 3 4 3 4 2 Changing...

Страница 4: ...anel 3 1 4 Probe Well Styles 3 2 5 Right Side Panel 3 3 6 Rear Panel 3 3 7 Controller Parameter Factory Default Settings 3 5 8 Approximate Probe Well Heat Up Cool Down Transition Times 3 5 9 Calibrato...

Страница 5: ...nect main power cord or main power source when unit is still hot Do not connect and or operate this unit to a non grounded non polarized outlet or power source This unit is intended for indoor use onl...

Страница 6: ...y appropriate device upon verification of compliance 1 5 General Description The CL1000 is a portable rugged benchtop dry block calibration source with a built in precision PID digital controller The...

Страница 7: ...unting Mount the unit in an ambient environment between the specified 32 to 122 F 0 to 50 C on a bench table top or shelf in a horizontal position and operate at least ten inches from any air obstruct...

Страница 8: ...ower Connection and Requirements Electrical connections and wiring should be performed only by suitably trained personnel Connect to a stable earth grounded AC mains supply of the correct voltage for...

Страница 9: ...s 2 4 2 International 230 VAC 50 60 Hz Models On 230VAC models an International style power cord with the proper color code and approvals is provided with stripped wire ends for connection to the prop...

Страница 10: ...CL1000 Series Installation 2 2 4 Notes...

Страница 11: ...is at a safe temperature for power removal or storage After inserting or removing probes into the probe well allow the calibrator time to stabilize before making your measurement Adding or removing p...

Страница 12: ...be a heater or refrigerator As the process temperature approaches the setpoint temperature the hot or cold process will be pulsed to reduce the corrective measures and minimize overshooting The contro...

Страница 13: ...on then press the reset button firmly If this does not correct the problem contact the factory 3 3 Rear Panel Controls and Connections Figure 6 Rear Panel 3 3 1 AC Power Input The customer connects t...

Страница 14: ...oint temperature to advance more rapidly to a desired value The minimum and maximum setpoints are locked out at 0 and 260 C 32 and 500 F respectively Do not re program the controller s parameter setti...

Страница 15: ...get plate temperature and go to the appropriate column Note that there are X s along the diagonal to ensure the original and target temperatures are the same 3 5 LEVEL 1 LEVEL 2 LEVEL 3 TUNE OFF SP1 P...

Страница 16: ...ell and place it on a protected surface to cool If you have another probe to calibrate place it into the probe well and allow the calibrator a few minutes to re stabilize 3 8 Cooling Down Your Calibra...

Страница 17: ...between your benchtop calibrator and PC Figure 10 Wiring Connections from Calibrator to PC 4 3 CN9 SW Communication Software Calibrators with the C2 option come complete with communication software OM...

Страница 18: ...Fan The fan guard should be cleaned as a minimum annually by using a compressed air source 5 3 Fuse Replacement Disconnect all power from source before attempting fuse replacement For continued prote...

Страница 19: ...2 to 122 F Humidity 0 to 80 RH non condensing Internal Control Sensor Platinum RTD 100 00385 Class A Power Requirements Model CL1000A B C D 3 15 Amps 115 VAC 10 50 60 Hz 275W Model CL1000A B C D 230 V...

Страница 20: ...r is set to its factory default settings c An overheat condition may have occurred Refer to section 3 3 d Unit requires service contact our customer service department 3 Display flashing inPt a Unit r...

Страница 21: ...actual value being measured IEC International Electrotechnical Commission NIST National Institute of Standards and Technology PID Proportional Integral Derivative A three mode control action where the...

Страница 22: ...top design Low cost Model CL900A hot point Dry Block Probe Calibrator Temperature Range ambient 22 to 482 C ambient 40 to 900 F Accuracy 1 5 F Control Stability 0 3 F Power 115 or 230 VAC 10 50 60 Hz...

Страница 23: ...by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limit...

Страница 24: ...bine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industri...