Technical data 

Type 

EMD 

HP 

230V 

EMD  

HP A 

230V 

EMD  

HP C 

230V 

EMD  

HP 

115V 

EMD  

HP A 

115V 

EMD  

HP C 

115V 

EMD  

HP 

24Vac 

EMD  

HP A 

24Vac 

EMD  

HP A 

24Vdc 

Service Network 

Connection  

No 

No 

Yes 

No 

No 

Yes 

No 

No 

No 

Alarm output 

No 

Yes 

Yes 

No 

Yes 

Yes 

No 

Yes 

Yes 

Voltage 

230V ac, 50 – 60Hz 

115V ac, 50 – 60Hz 

24V ac, 50 – 60Hz  24V dc 

Fuse inside EMD12 

5x20 1A T 

5x20 1A T 

2A 

2A 

Power 

25VA 

25VA 

22W 

Operating pressure 

range 

0 – 50 bar 

0 – 725 psi 

Drain capacity 

Kv 

30.4 l/h @ 50 bar, 0.018 cfm @ 725 psi 

4.3 (l/h) / √bar

 

Operating 

temperature range 

1,5°C – 65°C 

Protection class 

IP 54 

Inlet connection 

G 1/2" (parallel thread) 

Outlet connection 

G 1/4" (parallel thread) 

Mass 

2.3 kg 

 

Peak Compressor Capacity 

System pressure

 

Northern Europe, 

Canada, Central Asia 

Rest of the world 

Moist tropical and 

subtropical regions 

50 bar 

29.5 m

3

/min 

22.2 m

3

/min 

12.9 m

3

/min 

40 bar 

26.4 m

3

/min 

19.9 m

3

/min 

11.5 m

3

/min 

30 bar 

22.9 m

3

/min 

17.2 m

3

/min 

10.0 m

3

/min 

20 bar 

18.7 m

3

/min 

14.0 m

3

/min 

8.1 m

3

/min 

 

Содержание EMD HP

Страница 1: ...tions carefully before installing filter into service Trouble free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual are respected Install...

Страница 2: ...parts are intercepted The bottom can be removed from EMD HP for cleaning In the condensed water leaving the EMD HP there are still small particles of rust and remains of compressor oil Oil must be rem...

Страница 3: ...venting mode the valve is opened after the venting period has expired and trapped air is allowed to escape through drainage Now condensed water can reach water level sensor and EMD HP is opening its...

Страница 4: ...ng 100 x 1 5 9 Power Inlet gland 10 Sealing O Ring 12 x 2 0 11 Alarm inlet plug 12 Valve 13 Flow choke 14 Bracket 15 Washer 5 3 DIN125A 16 Screw M4x8 DIN912 17 Sealing O Ring 54 x 3 0 18 Back up ring...

Страница 5: ...22W Operating pressure range 0 50 bar 0 725 psi Drain capacity Kv 30 4 l h 50 bar 0 018 cfm 725 psi 4 3 l h bar Operating temperature range 1 5 C 65 C Protection class IP 54 Inlet connection G 1 2 par...

Страница 6: ...ly be carried out when electrical power supply is disconnected Electrical work must always be carried out by qualified electrician Do not exceed maximal operating pressure or operating temperature ran...

Страница 7: ...enance takes place The outlet of EMD HP s valve is connected to drainage system by suitable connection and pipe Pay attention that in case of clogged drainage pressure in it would rise up to the syste...

Страница 8: ...l drainage pipes must be inclined so that air could escape from EMD HP and that debriss is flushed toward EMD HP left When horizontal drainge pipes are long venting should be built right Electrical wi...

Страница 9: ...7V Power Connection 1 24Vac grounded line 2 24Vac 3 PE Conductor Valve Connection 4 PE Conductor 5 Power line 6 Power line Alarm output EMD HP A 7 Alarm Warning 9 GND Umax at high impedance 39V Imax...

Страница 10: ...device of heavy inductive load like compressor motor left Instead heavy inductive load and EMD HP should be protected separately right After installation or maintenance work press the test button to d...

Страница 11: ...its valve longer and more frequently and its capacity is doubled When EMD HP is still not able to discharge all the water in 5min it enters alarm mode In alarm mode EMD HP opens its valve so that it w...

Страница 12: ...twork Reader SN 10 200 It s a handheld device that allows user to send command messages manually It also comprises a display where answer to command are read In the table in next page command message...

Страница 13: ...ensor adjustment data 0xC0 Current working parameters 0xE0 0xF0 Settings 0xE4 Timed Venting valve opened period Values 0 6s 0 8s 1 2s 1 7s 2 4s Timed venting off default 0xE8 Timed Venting Period to f...

Страница 14: ...s integrity Clean also O ring sealing and its gland thoroughly Otherwise strainer sealing may start to leak Be careful while cleaning because solid particles in debris may be sharp Reattach bottom cov...

Страница 15: ...r The valve assembly should be cleaned or replaced by authorized person Long flashes of green LED indicate full tank although the tank is empty Clean the water level sensor surface EMD is in alarm and...

Страница 16: ...n The guarantee shall be void if The installation and operating manual was not followed with respect to installation initial commissioning and maintenance The unit was not operated properly and approp...