The main mode of operation is a water level triggered discharging. The valve opens when 

water level in EMD HP’s tank reaches threshold and it closes back before the tank is empty. 

This way, only condensed water is discharged and no compressed air is lost.  

In the timed venting mode, the valve is opened when water level reaches threshold, too. 

Besides, when the valve is closed  continuously  for a predetermined  period, it is opened 

shortly although there is no water in the tank. During working day, water in EMD HP collects 

rapidly so that venting period would never expire  and there are no air losses. When 

production rests, EMD HP  is opening its valve. But since these discharges  are short and 

sparse, air losses are small. The timed venting mode should be used when there is a lot of 

debris in condensed water and piping upward the  EMD HP  could not be inclined enough. 

Such situation is quite common under pressure vessels. It may happen  that air  could not 

escape from the tank upward the piping and while there is air around water level sensor, the 

EMD HP would never open. In the timed venting mode, the valve is opened after the venting 

period has expired and trapped air is allowed to escape through drainage. Now, condensed 

water can reach water level sensor and EMD HP is opening its valve until all collected water 

is discharged. 

The timed venting mode is disabled initially since situations when this mode is needed are 

rare. The mode could be enabled through the service network.  

To service network, only types of EMD HP with communication electronics built in could be 

connected.  The service network is  used for uploading data that are collected in  EMD HP 

during  its operation.  The data are  elapsed hours,  number of water discharging, current 

water level in the tank and other data that could help to supervise and troubleshoot the 

system.  Through the service network, some operating parameters of EMD HP  like venting 

period in timed venting mode could be set. Additionally, valve could be operated remotely. 

Features: 

 

No loss drain 

 

EMD HP could be fixed horizontally or vertically 

 

Strainer integrated in the bottom cover of water tank 

 

Optional time venting mode of operation 

 

Optional Alarm/ Warning output and Service Network Protocol for remote 

surveillance 

 

Elapsed hour counter, valve operating counter and other data collection 

 

Easy replacement of parts due to wear 

 

Содержание EMD HP

Страница 1: ...tions carefully before installing filter into service Trouble free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual are respected Install...

Страница 2: ...parts are intercepted The bottom can be removed from EMD HP for cleaning In the condensed water leaving the EMD HP there are still small particles of rust and remains of compressor oil Oil must be rem...

Страница 3: ...venting mode the valve is opened after the venting period has expired and trapped air is allowed to escape through drainage Now condensed water can reach water level sensor and EMD HP is opening its...

Страница 4: ...ng 100 x 1 5 9 Power Inlet gland 10 Sealing O Ring 12 x 2 0 11 Alarm inlet plug 12 Valve 13 Flow choke 14 Bracket 15 Washer 5 3 DIN125A 16 Screw M4x8 DIN912 17 Sealing O Ring 54 x 3 0 18 Back up ring...

Страница 5: ...22W Operating pressure range 0 50 bar 0 725 psi Drain capacity Kv 30 4 l h 50 bar 0 018 cfm 725 psi 4 3 l h bar Operating temperature range 1 5 C 65 C Protection class IP 54 Inlet connection G 1 2 par...

Страница 6: ...ly be carried out when electrical power supply is disconnected Electrical work must always be carried out by qualified electrician Do not exceed maximal operating pressure or operating temperature ran...

Страница 7: ...enance takes place The outlet of EMD HP s valve is connected to drainage system by suitable connection and pipe Pay attention that in case of clogged drainage pressure in it would rise up to the syste...

Страница 8: ...l drainage pipes must be inclined so that air could escape from EMD HP and that debriss is flushed toward EMD HP left When horizontal drainge pipes are long venting should be built right Electrical wi...

Страница 9: ...7V Power Connection 1 24Vac grounded line 2 24Vac 3 PE Conductor Valve Connection 4 PE Conductor 5 Power line 6 Power line Alarm output EMD HP A 7 Alarm Warning 9 GND Umax at high impedance 39V Imax...

Страница 10: ...device of heavy inductive load like compressor motor left Instead heavy inductive load and EMD HP should be protected separately right After installation or maintenance work press the test button to d...

Страница 11: ...its valve longer and more frequently and its capacity is doubled When EMD HP is still not able to discharge all the water in 5min it enters alarm mode In alarm mode EMD HP opens its valve so that it w...

Страница 12: ...twork Reader SN 10 200 It s a handheld device that allows user to send command messages manually It also comprises a display where answer to command are read In the table in next page command message...

Страница 13: ...ensor adjustment data 0xC0 Current working parameters 0xE0 0xF0 Settings 0xE4 Timed Venting valve opened period Values 0 6s 0 8s 1 2s 1 7s 2 4s Timed venting off default 0xE8 Timed Venting Period to f...

Страница 14: ...s integrity Clean also O ring sealing and its gland thoroughly Otherwise strainer sealing may start to leak Be careful while cleaning because solid particles in debris may be sharp Reattach bottom cov...

Страница 15: ...r The valve assembly should be cleaned or replaced by authorized person Long flashes of green LED indicate full tank although the tank is empty Clean the water level sensor surface EMD is in alarm and...

Страница 16: ...n The guarantee shall be void if The installation and operating manual was not followed with respect to installation initial commissioning and maintenance The unit was not operated properly and approp...

Отзывы: