Do not connect several condensed water sources to one drain device because air would bypass filtering
(left). Instead, each spot where condensed water collects must have its own condensate drain device
(right).
Drainage piping must be built without traps that would trap air in the EMD HP and prevent condensed
water to enter it (left). Additional venting would not help because debriss collects in the lowest part of
drainge pipe and clogg it (right).
Horizontal drainage pipes must be inclined so that air could escape from EMD HP and that debriss is
flushed toward EMD HP (left). When horizontal drainge pipes are long, venting should be built (right).
Electrical wiring:
Fully disconnect power from EMD HP before opening the cover of electronic compartment.
Please ensure that the installation is carried out according to valid regulations.
Power Connection Cable
2 x 0,75mm
2
+ PE
Oil resistant insulation recomended
Wires should be equipped with appropriate
ferrules. Make sure, that all strands of a wire are
fitted inside the ferrule.
Make sure that all wires are fitted into terminals
firmly!
EMD12
EMD12
EMD12
EMD12
8 mm