Appropriate use 

AAFs series filters are designed for high efficient removal of solid particles, water, 
oil aerosols, hydrocarbons, odour and vapours from compressed air systems. This 
appliance must be used only for the purpose for which it was specifically 

designed. All other uses are to be considered incorrect. 

Specifically: 

 

The filter is not intended for human breathing without proper additional 
equipment. 

 

The f

ilter can only be used for “GROUPE 2” fluids (

PED 2014/68/EU). 

 

The filter can not be used for explosive, toxic, flammable, corrosive and 

“GROUPE 1” fluids (PED 

2014/68/EU). 

Warning: internal corrosion can seriously reduce the safety of installation: check it while 
changing the cartridge. 

The manufacturer will under no circumstances be responsible for any damage resulting from 
improper, incorrect or unreasonable use. 

Use genuine spare parts only. Any damage or malfunction caused by the use of ungenuine 
parts is not covered by Warranty or Product Liability. 

The filter and filter elements must be stored indoors in a dry place. Store them in original 
packing until they are used. 

 

 

 

 

 

 

 

 

 

 

 

Содержание AAFs 0006

Страница 1: ...owing instructions carefully before installing the filter into the service Trouble free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual...

Страница 2: ...icator optional 2 Screw 3 Flat seal 4 Head cover 5 Filter head 6 O ring seal 7 Filter or cyclone element 8 Condensate drain optional 9 Filter bowl Filter housing size 0006 0016 does not contain the co...

Страница 3: ...erating temperature 1 5 65 C 35 149 F Operating pressure 0 16 bar g 0 232 psi MATERIALS Housing material Aluminium Fittings Screws Brass Brass zinc plated Steel Cover ABS Sealing NBR silicone free Cor...

Страница 4: ...o ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded The filter has been designed for primarily static...

Страница 5: ...GROUPE 2 fluids PED 2014 68 EU The filter can not be used for explosive toxic flammable corrosive and GROUPE 1 fluids PED 2014 68 EU Warning internal corrosion can seriously reduce the safety of inst...

Страница 6: ...personnel Never operate with installation under pressure The user is responsible for ensuring that the filter will never operate at a pressure exceeding the nominal values Eventual over pressure coul...

Страница 7: ...rtridge on the filter head simply by pressing Tightness is ensured by one o ring silicone free Fit the filter bowl and tight it accurately Filters must always be installed in a vertical position with...

Страница 8: ...8 Changing the filter element...

Страница 9: ...se unsuitable tools to open and close the filter housings The housing O ring can be damaged during filter element change To prevent air leakage and malfunction replace the housing O ring if necessary...

Страница 10: ...ment parts were used The unit was not operated within the permissible technical parameters Unauthorised constructional changes were made to the unit or if parts of the unit that may not be opened were...