background image

Technical data 

FILTER 

HOUSING 

PIPE SIZE 

[inch] 

FILTER 

ELEMENT 

FLOW CAPACITY 

DIMENSIONS [mm] 

VOLUME 

[l] 

WEIGHT 

[kg] 

[Nm

3

/h] 

[scfm] 

AAFs 0006 

1/8 

03528 

10 

105 

55 

14 

50 

0,07 

0,23 

AAFs 0016 

1/4 

05528 

18 

11 

125 

55 

14 

70 

0,09 

0,24 

AAFs 0026 

1/4 

03844 

25 

15 

145 

73 

18 

50 

0,22 

0,42 

AAFs 0036 

3/8 

03844 

30 

18 

145 

73 

18 

50 

0,22 

0,42 

AAFs 0046 

1/4 

06050 

35 

22 

189 

88 

32 

60 

0,44 

0,72 

AAFs 0056 

3/8 

06050 

60 

35 

189 

88 

32 

60 

0,45 

0,71 

AAFs 0076 

1/2 

07050 

78 

46 

189 

88 

32 

80 

0,45 

0,70 

AAFs 0106 

3/4 

14050 

120 

70 

257 

88 

32 

150 

0,64 

0,78 

AAFs 0186 

12075 

198 

116 

261 

125 

37 

160 

1,4 

1,9 

AAFs 0306 

22075 

335 

197 

361 

125 

37 

250 

2,0 

2,3 

AAFs 0476 

1 1/2 

32075 

510 

300 

461 

125 

37 

350 

2,6 

2,5 

AAFs 0706 

1 1/2  

50075 

780 

459 

641 

125 

37 

530 

3,6 

3,2 

Flow capacity at 7 bar(g), 20°C

 

 
 
 

Operating temperature 

1,5 - 

65 °C

 

35 - 

149 °F

 

Operating pressure

 

0 - 16 bar(g) 

0 - 232 psi 

MATERIALS 

Housing material 

Aluminium 

Fittings, Screws 

Brass, Brass-zinc plated, Steel 

Cover 

ABS 

Sealing 

NBR (silicone free) 

Corrosion protection 

Electrophoretic Coating (KTL) 

Outside protection 

Powder paint coated (Epoxi-polyester base)  

Lubricant 

CORRECTION FACTORS

 

To calculate the correct capacity of a given filter based on actual operating conditions, 
multiply the nominal flow capacity by the appropriate correction factor(s).  
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x COP 

 

[bar] 

10 

11 

12 

13 

14 

15 

16 

[psi] 

29 

44 

58 

72 

87 

100 

115 

130 

145 

160 

174 

189 

203 

218 

232 

C

OP 

0,38 

0,5 

0,63  0,75  0,88 

1,13  1,25  1,38  1,50  1,63  1,75  1,88  2,00  2,13 

 
PRESSURE EQUIPMENT DIRECTIVE PED 2014/68/EU (Fluid group 2) 

AAFs 0006 - AAFs 0476 

Not required 

AAFs 0706 

Category 1, Module A 

There is a Technical datasheet available for additional technical specifications, contact manufacturer. 

 

 

B

C

A

D

G 1/2"

Содержание AAFs 0006

Страница 1: ...owing instructions carefully before installing the filter into the service Trouble free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual...

Страница 2: ...icator optional 2 Screw 3 Flat seal 4 Head cover 5 Filter head 6 O ring seal 7 Filter or cyclone element 8 Condensate drain optional 9 Filter bowl Filter housing size 0006 0016 does not contain the co...

Страница 3: ...erating temperature 1 5 65 C 35 149 F Operating pressure 0 16 bar g 0 232 psi MATERIALS Housing material Aluminium Fittings Screws Brass Brass zinc plated Steel Cover ABS Sealing NBR silicone free Cor...

Страница 4: ...o ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded The filter has been designed for primarily static...

Страница 5: ...GROUPE 2 fluids PED 2014 68 EU The filter can not be used for explosive toxic flammable corrosive and GROUPE 1 fluids PED 2014 68 EU Warning internal corrosion can seriously reduce the safety of inst...

Страница 6: ...personnel Never operate with installation under pressure The user is responsible for ensuring that the filter will never operate at a pressure exceeding the nominal values Eventual over pressure coul...

Страница 7: ...rtridge on the filter head simply by pressing Tightness is ensured by one o ring silicone free Fit the filter bowl and tight it accurately Filters must always be installed in a vertical position with...

Страница 8: ...8 Changing the filter element...

Страница 9: ...se unsuitable tools to open and close the filter housings The housing O ring can be damaged during filter element change To prevent air leakage and malfunction replace the housing O ring if necessary...

Страница 10: ...ment parts were used The unit was not operated within the permissible technical parameters Unauthorised constructional changes were made to the unit or if parts of the unit that may not be opened were...

Отзывы: