3
Technical data
FILTER
HOUSING
PIPE SIZE
[inch]
FILTER
ELEMENT
FLOW CAPACITY
DIMENSIONS [mm]
VOLUME
[l]
WEIGHT
[kg]
[Nm
3
/h]
[scfm]
A
B
C
D
AAFs 0006
1/8
03528
10
6
105
55
14
50
0,07
0,23
AAFs 0016
1/4
05528
18
11
125
55
14
70
0,09
0,24
AAFs 0026
1/4
03844
25
15
145
73
18
50
0,22
0,42
AAFs 0036
3/8
03844
30
18
145
73
18
50
0,22
0,42
AAFs 0046
1/4
06050
35
22
189
88
32
60
0,44
0,72
AAFs 0056
3/8
06050
60
35
189
88
32
60
0,45
0,71
AAFs 0076
1/2
07050
78
46
189
88
32
80
0,45
0,70
AAFs 0106
3/4
14050
120
70
257
88
32
150
0,64
0,78
AAFs 0186
1
12075
198
116
261
125
37
160
1,4
1,9
AAFs 0306
1
22075
335
197
361
125
37
250
2,0
2,3
AAFs 0476
1 1/2
32075
510
300
461
125
37
350
2,6
2,5
AAFs 0706
1 1/2
50075
780
459
641
125
37
530
3,6
3,2
Flow capacity at 7 bar(g), 20°C
Operating temperature
1,5 -
65 °C
35 -
149 °F
Operating pressure
0 - 16 bar(g)
0 - 232 psi
MATERIALS
Housing material
Aluminium
Fittings, Screws
Brass, Brass-zinc plated, Steel
Cover
ABS
Sealing
NBR (silicone free)
Corrosion protection
Electrophoretic Coating (KTL)
Outside protection
Powder paint coated (Epoxi-polyester base)
Lubricant
/
CORRECTION FACTORS
To calculate the correct capacity of a given filter based on actual operating conditions,
multiply the nominal flow capacity by the appropriate correction factor(s).
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x COP
[bar]
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
[psi]
29
44
58
72
87
100
115
130
145
160
174
189
203
218
232
C
OP
0,38
0,5
0,63 0,75 0,88
1
1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
PRESSURE EQUIPMENT DIRECTIVE PED 2014/68/EU (Fluid group 2)
AAFs 0006 - AAFs 0476
Not required
AAFs 0706
Category 1, Module A
There is a Technical datasheet available for additional technical specifications, contact manufacturer.
B
C
A
D
G 1/2"
Содержание AAFs 0006
Страница 8: ...8 Changing the filter element...