The filter assembly and installation procedures are as follows: 

 

Depressurize the system before carrying out the installation work. 

 

Connect the filter head to the compressed air piping and check that the airflow 
corresponds to the direction of the arrow positioned on the filter head cap. 

 

Lubricate the O-ring and the sealing surfaces of the filter head and cartridge use 
silicone-free grease. 

 

Fit the filter cartridge on the filter head simply by pressing. Tightness is ensured by 
one o-ring (silicone free). 

 

Fit the filter bowl and tight it accurately. 

 

Filters must always be installed in a vertical position with sufficient space around. The 
minimum distance (D in the technical data table) has to be assured under the filter 
bowl, which is necessary for filter cartridge change. 

 

Stick the adhesive label showing the month and year for the next filtering element 
change (max. one year) on the filter bowl. 

 

Slowly pressurize the installation and check it for air leakage. 

 

Ensure that filter is not be subjected to mechanical stress. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание AAFs 0006

Страница 1: ...owing instructions carefully before installing the filter into the service Trouble free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual...

Страница 2: ...icator optional 2 Screw 3 Flat seal 4 Head cover 5 Filter head 6 O ring seal 7 Filter or cyclone element 8 Condensate drain optional 9 Filter bowl Filter housing size 0006 0016 does not contain the co...

Страница 3: ...erating temperature 1 5 65 C 35 149 F Operating pressure 0 16 bar g 0 232 psi MATERIALS Housing material Aluminium Fittings Screws Brass Brass zinc plated Steel Cover ABS Sealing NBR silicone free Cor...

Страница 4: ...o ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded The filter has been designed for primarily static...

Страница 5: ...GROUPE 2 fluids PED 2014 68 EU The filter can not be used for explosive toxic flammable corrosive and GROUPE 1 fluids PED 2014 68 EU Warning internal corrosion can seriously reduce the safety of inst...

Страница 6: ...personnel Never operate with installation under pressure The user is responsible for ensuring that the filter will never operate at a pressure exceeding the nominal values Eventual over pressure coul...

Страница 7: ...rtridge on the filter head simply by pressing Tightness is ensured by one o ring silicone free Fit the filter bowl and tight it accurately Filters must always be installed in a vertical position with...

Страница 8: ...8 Changing the filter element...

Страница 9: ...se unsuitable tools to open and close the filter housings The housing O ring can be damaged during filter element change To prevent air leakage and malfunction replace the housing O ring if necessary...

Страница 10: ...ment parts were used The unit was not operated within the permissible technical parameters Unauthorised constructional changes were made to the unit or if parts of the unit that may not be opened were...

Отзывы: