Safety instructions 

 

The relevant safety at work and accident prevention 
regulations, plus operating instructions, shall apply for 
operating the filter. The filter has been constructed in 
accordance with the generally recognized rules of 

engineering. It complies with the requirements of directive 2014/68/EU concerning pressure 
equipment. 

Ensure that installation complies with local laws for operation and routine testing of 
pressure equipment at the place of installation. 

The Operator/user of the filter should make himself familiar with the function, installation, 
and start-up of the unit. All the safety information is always intended to ensure your 
personal safety. 

 

Do not exceed the max. Operating pressure or operating temperature range 
(see data label). 

 

The permissible working temperatures and pressures for ad-on parts and 
filter elements are given under Technical data for those ad-ons. Maximum 
temperature and pressure for the assembled system are the lowest of any 
individual part. 

 

It is necessary to ensure that the unit is equipped with the corresponding 
safety and test devices to prevent the permissible operating parameters from 
being exceeded. 

 

The filter has been designed for primarily static pressure. Rapid changes of 
pressure are not allowed. 

 

Ensure that the filter is not subject to vibrations that could cause fatigue 
fractures. 

 

The filter is not to be subjected to mechanical stresses. 

 

The medium used may not have any corrosive components that could attack 
the materials of the filter in a way that is not permitted. Do not use the filter 
in hazardous areas with potentially explosive atmospheres. 

 

All installation and maintenance work on the filter may only be carried out by 
trained and experienced specialists. 

 

It is forbidden to carry out any kind of work on the filter and piping, including 
welding and constructional changes, etc. 

 

A pressure gauge, which shows the operational pressure, must be installed in 
the unit, respectively, in the pipeline. 

 

Depressurize the system before carrying out the installation work.  

 

The unit must be installed vertically in the piping. 

 

Ensure that filter is installed without any stress. 

 

Use original spare parts only. 

 

Use the device for the appropriate purpose only. 
 

 

Содержание AAFs 0006

Страница 1: ...owing instructions carefully before installing the filter into the service Trouble free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual...

Страница 2: ...icator optional 2 Screw 3 Flat seal 4 Head cover 5 Filter head 6 O ring seal 7 Filter or cyclone element 8 Condensate drain optional 9 Filter bowl Filter housing size 0006 0016 does not contain the co...

Страница 3: ...erating temperature 1 5 65 C 35 149 F Operating pressure 0 16 bar g 0 232 psi MATERIALS Housing material Aluminium Fittings Screws Brass Brass zinc plated Steel Cover ABS Sealing NBR silicone free Cor...

Страница 4: ...o ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded The filter has been designed for primarily static...

Страница 5: ...GROUPE 2 fluids PED 2014 68 EU The filter can not be used for explosive toxic flammable corrosive and GROUPE 1 fluids PED 2014 68 EU Warning internal corrosion can seriously reduce the safety of inst...

Страница 6: ...personnel Never operate with installation under pressure The user is responsible for ensuring that the filter will never operate at a pressure exceeding the nominal values Eventual over pressure coul...

Страница 7: ...rtridge on the filter head simply by pressing Tightness is ensured by one o ring silicone free Fit the filter bowl and tight it accurately Filters must always be installed in a vertical position with...

Страница 8: ...8 Changing the filter element...

Страница 9: ...se unsuitable tools to open and close the filter housings The housing O ring can be damaged during filter element change To prevent air leakage and malfunction replace the housing O ring if necessary...

Страница 10: ...ment parts were used The unit was not operated within the permissible technical parameters Unauthorised constructional changes were made to the unit or if parts of the unit that may not be opened were...

Отзывы: