13
MATERIALS
Consoles
Steel
Control blocks
Aluminium
Tower tubes
Aluminium
Panels
Steel
Control valve seats
Aluminium
Non-return valve
Aluminium, Steel, PA (polyamide)
Sealing
NBR
Adsorption material
Silica gel
Corrosion protection
Anodized
Outside protection
Powder paint coated (Epoxy-polyester base)
Lubricant
Shell cassida grease RLS 2
End-caps
PA6
Controller Housing
ABS
CORRECTION FACTORS
To calculate the correct flow capacity of a given device based on actual operating conditions,
multiply the nominal flow capacity by the appropriate correction factor(s).
Example:
Corrected flow capacity for nominal flow capacity of 36 Nm
3
/h at operating
pressure of 6 bar(g) and inlet temperature of 40 °C would be:
0,88
0, 97
36
ℎ
⁄
30,73
ℎ
⁄
CORRECTION FACTOR – OPERATING PRESSURE
[bar]
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
[psi]
29
44
59
73
88
103
118
132
147
162
176
191
206
220
235
C
OP
0,38
0,5
0,6
0,75
0,88
1
1,13
1,25
1,38
1,5
1,63
1,75
1,88
2
2,1
CORRECTION FACTOR – INLET TEMPERATURE
[°C]
25
30
35
40
45
50
C
IT
1,00
1,00
1,00
0,97
0,87
0,80
Содержание A-DRY Series
Страница 2: ...2...
Страница 16: ...16...
Страница 37: ...37 5 9 1...
Страница 38: ...38 Console layout for DRY 6 DRY 12 DRY 24 and DRY 36 Console layout for DRY 60 DRY 75 and DRY 105 9 3 9 2...
Страница 46: ...46 13 6 13 7...
Страница 48: ...48 Normally open valve Normally closed valve 13 10 13 11...
Страница 50: ...50 13 15...
Страница 56: ...56 14 6 14 7...
Страница 63: ...63 16 Maintenance record TYPE OF MAINTENANCE DATE SIGNATURE NOTES Commissioned...
Страница 64: ...64...