32
Care and maintenance
The glass radiation heater is designed in such a way that the heat is emitted in the form of radiation
through the glass panel. It does not contain any parts that require regular maintenance.
To clean the glass radiation heater we recommend using a conventional glass cleaner. Do not use
abrasive detergents, as this could cause scratches to the class and the coated surfaces of the
appliance.
Caution:
Before cleaning the heater, ensure that it has cooled down!
Technical data
Model
Dimensions
HxWxD
(mm)
Rated voltage
Power
consumption
(W)
Protection
rating
Protection
class
Weight
(kg)
15/2251
445x 600x59
180
8
15/2261 445x1000x59
310
14
15/2271 445x1400x59
440
19
15/2281 445x1800x59
570
25
15/2351
600x 600x59
270
11
15/2361 600x1000x59
470
19
15/2371 600x1400x59
670
26
15/2381 600x1800x59
1/N/PE 230V
870
IP24*
Spray
Water
protection
I
Earth
conductor
connection
34
* protection rating IP24 only if installed on wall; protection rating IP20 for ceiling installation
Troubleshooting
Appliance fails to heat:
•
Fuse tripped or defective?
•
External switch on?
•
Nominal temperature of room thermostat set to a temperature that is below the actual room
temperature?
Heat radiation too low:
•
Distance between glass radiation heater and person too big?
•
Appliance too small?
•
Objects placed between the glass radiation heater and the person?
Rating plate
The technical data specific to this model are specified on the rating plate. The plate is located at the top
or the left of the appliance, depending on its installation.
Model number
Serial number
Weight
Содержание Orayonne
Страница 87: ...87 ...