8. Utility Mode
Field Service Ver. 1.0 Jun. 2008
126
Adjustment / Setting
8.6
Admin. (Administrator Management)
• The Admin. setting will be available by entering the administrator password (8 digits) set
by the Admin. setting or Service Mode.
(The administrator password is initially set to “12345678.”)
8.6.1
System Settings
A. Power Save Settings
(1) Auto Reset
(2) Low Power Mode Settings
(3) Sleep Mode Settings
(4) LCD Back-Light OFF
Functions
• To set the period of time until auto reset function starts after finished operating with
keys.
Use
• To change the period of time until auto reset function starts.
• Auto reset during alarm resets the setting value for the current operation. Alarm sta-
tus as well as alarm display stay.
Setting/
Procedure
• The default setting is 1 min.
OFF
30 second
“1” to 240 M.
Functions
• To set the time until low power starts operating after the last key operation has been
completed.
• Low power: To turn LED and LCD OFF, and lower the power consumption.
Use
• To change the time until low power starts.
Setting/
Procedure
• Use the 10-key pad for setting.
• The default setting is 10 min.
“10 M.” (1 to 240 M.)
Functions
• To set the time until sleep mode starts operating after the last key operation has been
completed.
• Turn all lines OFF except 5 V line for control.
• “OFF” will only be displayed when “No Sleep” in Service Mode is set.
Use
• To change the time until the sleep mode starts.
Setting/
Procedure
• Use the 10-key pad for setting.
• The default setting is 20 min.
“20 M.” (1 to 240 M.) / OFF
Functions
• To set the period of time until the control panel turns off when operation with keys is
finished.
Use
Setting/
Procedure
• The default setting is 1 min.
“1 M.” (1 to 240 M.)
d-Color MF201