Field Service Ver. 1.0 Jun. 2008
10. Service Mode
237
Adjustment / Setting
Mode
Default value
471
Bit
7654 3210
HEX: 00 (for Europe)
HEX: 01 (for U.S)
State
0000 0000 (for Europe)
0000 0001 (for U.S)
Bit
Setting item
Setting value
Description
0
1
2-1
Set whether to display the account list screen
by default
Specify whether to display the account list
screen for machine authentication by default.
00
Not display list screen
01
Not available
10
Not available
11
Display list screen by
default
0
Display default for specifying scan range
mm
inch
Mode
Default value
473
Bit
7654 3210
HEX: 40
State
0100 0000
Bit
Setting item
Setting value
Description
0
1
7
Set priority job list screen
Display
by status
Display
by print
order
Set whether to prioritize
the print order display.
6
Specify treatment of # when entering destina-
tion
Specifies the use of the pound key (#).
Logic 0: Not used for abbreviated dialing.
Merely used as a symbol key.
Logic 1: Used for abbreviated dialing.
Use as #
for full
dialing
Use as
abbrevi-
ated dial-
ing
d
-Color
M
F
201
Y109660-1 Sevice Manual