Field Service Ver. 1.0 Jun. 2008
10. Service Mode
193
Adjustment / Setting
Mode
Default value
324
Bit
7654 3210
HEX: 10
State
0001 0000
Bit
Setting item
Setting value
Description
0
1
7-4
ACS parameter setting for ADF back side
posterior end (3).
0000
Parameter for specifically
detecting red (vermilion
seal)
0001
Parameter for specifically
detecting bright red and
blue
0010
Parameter for specifically
detecting green
0011
Parameter for specifically
detecting blue
0100
Parameter for specifically
detecting cyan
0101
Parameter for specifically
detecting magenta
0110
Parameter for specifically
detecting yellow
0111
Parameter for center
(closer to the full color)
1000
Parameter 1 closer to
black
1001
Parameter 2 closer to
black
1010
Parameter 3 closer to
black (closer to black)
others
Not available
Mode
Default value
325
Bit
7654 3210
HEX: 00
State
0000 0000
Bit
Setting item
Setting value
Description
0
1
7-6
ACS parameter setting for ADF back side
center (1).
00
Parameter for center
(closer to the full color)
01
Parameter 1 closer to
black
10
Parameter 2 closer to
black
11
Parameter 3 closer to
black (closer to black)
d
-Color
M
F
201
Y109660-1 Sevice Manual