10. Service Mode
Field Service Ver. 1.0 Jun. 2008
160
Adjustment / Setting
(4) Carriage Move
C. Shading Position
D. Test Copy
Functions
• To move the exposure unit to the arbitrary position.
Use
• Used for scanner operation test.
• Used when locking the scanner for transporting the main body.
Adjustment
Specification
<Absolute Position>
• Enter the shift distance (with unit of line) with home position sensor as reference to
move the exposure unit.
+838 to -10748 line (1 line increments)
* Home position of the exposure unit is [-827 line].
<Relative Position>
• Enter the shift distance (with unit of line) with the current exposure unit position as
reference to move the exposure unit.
-9999 to -9999 line (1 line increments)
* It protects to avoid the exposure unit from collision when the result calculated by the
current position and the entered value exceeds the absolute position area.
<Lock Posi.>
Pressing the [Lock Posi.] key moves the exposure unit to the lock position.
Adjustment
Instructions
Enter the + value when moving to the left.
Enter the - value when moving to the right.
Adjustment
Procedure
1.
Call the service mode to the screen.
2.
Touch these keys in this order: [Machine]
o
[Scan Area]
o
[BK-S Adjustment]
o
[Carriage Move].
3.
Select the function and enter the arbitrary shift distance if necessary, and press the
start key.
4.
The exposure unit moves.
Functions
• Not used.
Use
Setting/
Procedure
Functions
• To carry out test copy for adjustment.
Use
• To check the current status, effect, etc, when adjusting scanner area.
Setting/
Procedure
1.
Call the Service Mode to the screen.
2.
Touch [Machine Adjustment]
o
[Scan Area]
o
[Test Copy].
3.
Select the proper item for Paper, Simplex/Duplex, Color and Mixed Original, and
press the start key.
4.
The test copy is output.
d-Color MF201