690-NC2
0690S20042
3-2
The oven
must be
sealed to the mounting surface to comply with local sanitation codes.
For the purpose of sealing the unit a tube of NSF/FDA approved silicone sealant has
been provided with your unit. Apply, to the surface that the oven will rest on, a
continuous bead of sealant approximately 1/2 inch in from each of the four sides of the
oven. After the oven has been placed over this bead apply a second generous
continuous bead at the joint where the oven contacts the mounting surface thus totally
sealing the bottom of the oven to that surface.
Oven Setup
Ovens may be mounted to a fixed surface, attached to an “Oliver” oven rack with casters
or stacked. For associated mounting heights for the above options see figure 3.0 on
page 2-2.
CAUTION
USE CARE WHENEVER MOVING OVENS MOUNTED ON RACKS AS THEY ARE
TOP HEAVY AND PRESENT A TIPPING HAZARD.
Ovens attached to “Oliver” oven racks must be securely fixed to the rack with bolts.
Stacked ovens should be setup as shown on page 2-2 being sure that the alignment
pins on the top of the lower oven are securely positioned into the holes in the base of the
upper oven.
After the Oven has been mounted to a surface, attached to a rack, or stacked, remove
the shipping bracket, which secures the door. To remove the shipping bracket, remove
the two screws from the top of the door with a screwdriver and open the door. Replace
these screws and tighten securely. To remove the shipping bracket from the front of the
oven liner, remove the two hex head screws with a wrench. The bracket and screws
may be discarded. Replace the removed hex head screws with the two screws provided
in a bag taped to the floor of the oven chamber and tighten securely.
Electrical Connection
WARNING
THE OVEN MUST BE CONNECTED TO A PROPERLY GROUNDED ELECTRICAL
SOURCE OF THE SAME RATING AS THE MACHINE. FAILURE COULD RESULT IN
AN ELECTRICAL SHOCK WHICH MAY CAUSE INJURY OR DEATH.
WARNING
ALL WIRING AND ELECTRICAL REPAIRS SHOULD BE DONE BY A QUALIFIED
ELECTRICIAN. FAILURE TO DO SO MAY CAUSE SERIOUS INJURY OR DEATH.
Содержание NC
Страница 32: ...690 NC2 0690S20050 9 1 ELECTRICAL SUB PANEL Rev 2 27 09 ...
Страница 34: ...690 NC2 0690S20051 10 1 FRONT PANEL Revised 12 10 2012 ...
Страница 36: ...690 NC2 0690S20052 11 1 DOOR ASSEMBLY Rev 12 10 2012 ...
Страница 38: ...690 NC2 0690S20053 12 1 HOUSING CHAMBER ASSEMBLY ...
Страница 40: ...690 NC2 0690S20054 13 1 WATER SYSTEM ASSEMBLY ...
Страница 42: ...690 NC2 0690S20055 14 1 DAMPER CONTROL ASSEMBLY ...
Страница 44: ...690 NC2 0690S20056 15 1 208 240V WIRING DIAGRAM 0690D12025 Revised 2 27 09 ...
Страница 45: ...690 NC2 0690S20056 15 2 375 480V WIRING DIAGRAM 0690D12026 Revised 2 27 09 ...
Страница 46: ...690 NC2 0690S20056 15 3 INTERFACE BOARD SCHEMATICS ...