690-NC2
0690S20045
7-4
Replacing the Interior Door Gasket (Continued)
•
Replace gasket and use a NSF/FDA approve sealant between the metal and gasket.
and gasket end to end.
•
Set down door frame, rounded gasket side up and run a bead of NSF/FDA approved
sealant around top edge of entire gasket.
•
Place glass on top of gasket. This will seal the gasket to the glass.
•
Allow sealant to dry, (approximately four to five hours).
•
Replace door panel, clamp the front and back door panels together before tightening
the screws.
Changing an Electrical Component
WARNING
NEVER ATTEMPT TO SERVICE THIS OVEN UNTIL IT HAS BEEN DISCONNECTED
FROM THE POWER SUPPLY. ALL ELECTRICAL WORK MUST BE DONE BY A
QUALIFIED ELECTRICIAN.
•
Remove the front side panel which is located on the control side.
•
After identifying the component which needs to be replaced remove its wires after
marking them for ease of replacement.
•
Remove the component.
•
Re-install the component by reversing the removal procedures.
Rev. 4-28-2000
Содержание NC
Страница 32: ...690 NC2 0690S20050 9 1 ELECTRICAL SUB PANEL Rev 2 27 09 ...
Страница 34: ...690 NC2 0690S20051 10 1 FRONT PANEL Revised 12 10 2012 ...
Страница 36: ...690 NC2 0690S20052 11 1 DOOR ASSEMBLY Rev 12 10 2012 ...
Страница 38: ...690 NC2 0690S20053 12 1 HOUSING CHAMBER ASSEMBLY ...
Страница 40: ...690 NC2 0690S20054 13 1 WATER SYSTEM ASSEMBLY ...
Страница 42: ...690 NC2 0690S20055 14 1 DAMPER CONTROL ASSEMBLY ...
Страница 44: ...690 NC2 0690S20056 15 1 208 240V WIRING DIAGRAM 0690D12025 Revised 2 27 09 ...
Страница 45: ...690 NC2 0690S20056 15 2 375 480V WIRING DIAGRAM 0690D12026 Revised 2 27 09 ...
Страница 46: ...690 NC2 0690S20056 15 3 INTERFACE BOARD SCHEMATICS ...