600-R3
0600S20007.doc Rev. 5/2/02
MODEL 600-R3 SERIES DOUGH MOULDER
2.0 MACHINE INSTALLATION
2.1 Electrical Requirements
First, check the wall receptacle to be sure it is a three phase, 230 volt receptacle. If not,
one must be installed. Attach a three phase, 230 volt plug to the end of the power cord.
Be sure the pattern of the wall receptacle and pattern of the plug are matching.
NOTE
A TWIST-LOCK TYPE PLUG MUST BE USED ON THE 600-R3 SERIES OF
DOUGH MOULDERS POWER CORD TO KEEP IN COMPLIANCE WITH
ETL SAFETY REQUIREMENTS.
Before putting machine into operation, check to see if the machine is running in the
correct direction. (See Section 2.2).
2.2 Machine Running Direction
To check for proper running direction you must first disengage the heavy mat, (Item
#808, Assembly Drawing 5.1.1) by removing the left and right heavy mat support springs
(Item #809, Not Shown) from their posts located towards the top. Lay the heavy mat
and under lying felt over the front of machine. Then switch the machine on briefly and
observe the direction in which the front triangular belt is moving. If the belt is moving
upward the belt rotation is correct. If the belt is moving downward the machine’s running
direction must be reversed. Unplug the machine from the power receptacle. Reverse
the black and white wires in the plug at the end of the power cord.
When the running direction of the machine is correct reinstall the heavy mat.
Proper Running Direction
2-1