94MS20 Rev. B4
5-15
Shutter Removal
LT1 lampheads
•
Remove the 2 screws holding the air flow deflectors and remove them.
Then reach through the air tube and remove the thermostat, then the high
temp lamp lead (reaching through the bottom of the light a pair of
needlenose pliers to remove it from the lamp support assembly makes
this easier).
END
VIEW
•
Remove the 4 screws holding the rear reflector to the air tubes and remove
the reflector and lamp from the lamphead.
!
C
DO NOT TOUCH THE REFLECTOR SURFACE WITH
YOUR HANDS.
BOTTOM
VIEW
•
Remove the top screw from the cooling tube on both sides. Compress
the air tubes into the shutter assembly, remove the chain from the motor
sprocket, then remove the shutter assembly.
END
VIEW
•
Reassemble in reverse order.
!
C
DO NOT TOUCH THE REFLECTOR SURFACE WITH
YOUR HANDS.