5-2
94MS20 Rev. B4
Lamp Voltage
The lamp voltage measurement can provide useful information for lamp
striking, lamp output, and level switching information. The meter used
to measure can cause different results. We use caution when using digital
meters in our factory, due to the trigger pulses on the lamp before striking.
The waveforms are not sinusoidal, so different meters may produce
different results. Here is a chart with typical measurements:
M O D E L
I D L E
L O W
M E D
H I G H
T R I G .
I D L E / L O W
M E D .
H I G H
T R I G .
A L 1 5 w / L 1 1 5 0 A
1 8 0
1 8 0
- - - -
2 3 0
5 0 0 +
6 5 - 9 0
- - -
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 1 5 w / L 1 2 5 0
1 8 0
1 8 0
- - -
2 3 0
5 0 0 +
6 5 - 9 0
- - -
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 1 9 / 2 0 w / L 1 1 5 0 A
2 0 5
1 9 0
2 1 0
2 2 5
5 0 0 +
6 5 - 9 0
8 0 - 9 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 1 9 / 2 0 w / L 1 2 5 0 E
2 1 0
2 0 5
2 1 5
2 3 5
5 0 0 +
6 5 - 8 0
7 0 - 9 0
8 0 - 9 5
1 1 0 - 1 2 5
A L 2 3 w / L 1 2 5 0
2 0 5
1 9 0
2 1 0
2 2 5
5 0 0 +
6 5 - 9 0
8 0 - 9 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 2 3 w / L 1 2 5 2
2 1 0
2 0 5
2 1 5
2 2 5
5 0 0 +
6 5 - 8 0
7 0 - 9 0
8 0 - 9 5
1 1 0 - 1 2 5
A L 2 3 w / L 1 2 6 1
2 1 5
2 1 0
2 1 5
2 2 0
5 0 0 +
6 5 - 8 0
7 0 - 9 0
8 0 - 9 5
1 1 0 - 1 2 5
A L 2 5 / 2 5 - 2 w / L 1 2 5 0
1 9 0
1 9 0
- - -
2 3 0
5 0 0 +
4 5 - 8 0
- - -
1 0 0 - 1 2 5
1 1 0 - 1 2 5
A L 3 5 w / L 1 2 5 0
1 9 0
1 9 0
2 0 5
2 3 5
5 0 0 +
6 0 - 8 0
7 5 - 9 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 3 5 w / L 1 2 5 2
2 0 7
2 0 0
* 1 9 5
2 3 5
5 0 0 +
6 5 - 9 0
* 6 0 - 8 5
1 0 0 - 1 2 5
1 1 0 - 1 2 5
A L 3 5 w / L 1 2 6 1
2 0 0
1 9 5
* 1 9 5
2 3 5
5 0 0 +
6 5 - 9 0
* 6 0 - 8 5
1 0 0 - 1 2 5
1 1 0 - 1 2 5
A L 5 0 w / L 1 2 5 0
1 9 0
1 8 5
- - -
2 7 0
5 0 0 +
6 0 - 9 0
- - -
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 5 0 w / L 1 2 5 2
2 0 7
2 0 0
- - -
2 7 0
5 0 0 +
6 5 - 9 0
- - -
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 5 0 w / L 1 2 6 1
2 0 0
2 0 0
- - -
2 7 0
5 0 0 +
6 5 - 9 0
- - -
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 5 3 / 5 4 / 5 4 - 4 8 0 / 5 5 /
5 5 - 4 8 0 w / L 1 2 5 0
1 9 0
1 8 5
2 2 5
2 7 0
5 0 0 +
6 0 - 9 0
9 5 - 1 1 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 5 3 / 5 4 / 5 4 - 4 8 0 / 5 5 /
5 5 - 4 8 0 w / L 1 2 5 2
2 0 7
2 0 0
2 2 5
2 7 0
5 0 0 +
6 5 - 9 0
8 5 - 1 2 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 5 3 / 5 4 / 5 4 - 4 8 0 / 5 5 /
5 5 - 4 8 0 w / L 1 2 6 1
2 0 0
2 0 0
2 2 5
2 7 0
5 0 0 +
6 5 - 9 0
8 5 - 1 2 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 5 6 / 5 6 - 4 8 0 w / L 1 2 8 0
3 6 0 - 3 8 0
3 6 0 - 3 8 0
3 8 0 - 4 1 0
4 1 5 - 4 4 5
5 0 0 +
8 0 - 9 5
9 0 - 1 2 0
1 1 5 - 1 2 5
1 1 5 - 1 2 5
A L 5 6 / 5 6 - 4 8 0 w / L 1 2 8 1
4 0 0 - 4 3 0
4 0 0 - 4 3 0
4 2 0 - 4 9 0
4 4 0 - 5 1 0
5 0 0 +
8 0 - 9 0
9 0 - 1 2 0
1 1 5 - 1 2 5
1 1 5 - 1 2 5
A L 5 6 / 5 6 - 4 8 0 w / L 1 2 8 2
4 0 0 - 4 3 0
4 0 0 - 4 3 0
4 2 0 - 4 9 0
4 4 0 - 5 1 0
5 0 0 +
8 0 - 9 0
9 0 - 1 2 0
1 1 5 - 1 2 5
1 1 5 - 1 2 5
A L 8 3 / 8 4 / 8 4 - 4 8 0 / 8 5
w / L 1 2 8 0
3 7 0
3 6 0
3 9 0
4 2 5
7 0 0 +
8 0 - 1 0 5
9 0 - 1 2 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 8 3 / 8 4 / 8 4 - 4 8 0 / 8 5
w / L 1 2 8 1
4 1 5
3 9 5
4 2 5
4 8 5
7 0 0 +
8 0 - 1 1 5
9 0 - 1 2 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
A L 8 3 / 8 4 / 8 4 - 4 8 0 / 8 5
w / L 1 2 8 2
4 2 2
3 9 5
4 3 0
5 1 0
7 0 0 +
8 0 - 1 0 5
9 0 - 1 2 5
1 1 0 - 1 2 5
1 1 0 - 1 2 5
*When using the L1252 or L1261 the AL35 has only high and low power.
Lamp Power Path
The basic path that the power to the lamp takes is almost identical for all
units. The basic path is incoming line, main power relay, ballasts,
capacitors, trigger board, and then the lamp. See the point to point wiring
diagrams for each light source in section 7.
Содержание OLITE
Страница 1: ...94MS20 Rev B4 OLITE OLITE 60Hz Printing Light Service Manual O...
Страница 8: ...1 2 94MS20 Rev B4...
Страница 20: ...3 10 94MS20 Rev B4...
Страница 56: ...5 30 94MS20 Rev B4...
Страница 86: ...7 22 94MS20 Rev B5...
Страница 108: ...9 20 94MS20 Rev B4...
Страница 118: ...O Corporation 1850 East Saint Andrew Place Santa Ana Ca 92705 U S A Tel 714 258 5600 Fax 714 258 5601...