Chapter 5 Maintenance of Electrical Components
48
Document Version V1.1.2 (19/09/2022)
5.3
Replacement and maintenance of IO-free-distribution PCBA
IO-free-distribution PCBA is located in the base. To replace and maintain it, the base
interface panel needs to be removed. The position of IO-free-distribution PCBA is shown in
Figure 5-6 IO-free-distribution PCBA in the base
Tools and accessories: 2.5 mm Allen wrench, , static protective , diagonal pliers , cable
tie gloves.special assembly and disassembly tool for aviation
plug
Screw type: hexagon socket head cap screw (M3 * 8)
Step 1
Refer to Section 4.4 to remove the screws from the base interface panel of
the robot and gently pull out the base interface panel.
Step 2
Unplug all the cables connected to the IO-free-distribution PCBA.
IO-free-distribution
PCBA