7. Troubleshooting
(6-4) Jam occurs immediately after paper has reached the fuser.
Check item
Check work
Action to be taken at NG
(6-4-1) Motor operation check
Fuser motor
Confirm that the fuser motor works
normally by using the Motor & Clutch Test
of the self-diagnostic mode.
Check if any extra load exists or not.
PU PCB replacement
Replace the fuser
motor.
Replace the
fuser unit. If any
attempt of using
new fuser unit as
a trial is going to
be made, be sure
to use the System
Maintenance Menu
FUSE KEEP MODE.
(6-4-2) Temperature control of the roller rotation speed
Heat roller detected
temperature
Check the detected temperature of the heat
roller using the self-diagnostic mode. Is
abnormally high temperature or abnormally
temperature detected?
Replace fuser
unit, or relay PCB
(PRY PCB) or the
PU PCB. If any
attempt of using
new fuser unit as
a trial is going to
be made, be sure
to use the System
Maintenance Menu
FUSE KEEP MODE.
(6-4-3) Check the installation condition of fuser unit
Fuser unit
Check that the fuser unit is installed
normally. (Is it pushed in down to the
bottom-most point?)
Install the fuser unit
correctly in a printer.
7.5.2.(7) Paper running jam (error code 382)
(7-1) Jam occurs immediately after the power is turned on.
Check item
Check work
Action to be taken at NG
(7-1-1) Check the condition of the paper running path
Paper running path
of the multipurpose
tray
Check if paper is jammed or not in the
paper running path.
Remove the
jammed paper.
(7-1-2) Check condition of the mechanical parts
Check the sensor
lever of the WR
sensor.
Check if shape and movement of the
sensor levers have any abnormality or not.
Replace the sensor
lever with the good
sensor lever.
(7-1-3) Check condition of electrical parts
Check the detection
condition of the
sensor signal.
Confirm that the sensor signals are
normally detected by using the SWITCH
SCAN function of the self-diagnostic mode.
Replace the PU
PCB or EXIT sensor
or its cable or its
connection cable.
Check the output
signal level of the
EXIT sensor.
Check for the following signals at the
RELAY connector of the PU PCB.
Pin9: EXIT sensor
Confirm that the above signal levels change
when the sensor lever is operated.
Replace the EXIT
sensor.
Check the output
level of Fuser IN.
Check for the following signals at the
RELAY connector of the PU PCB.
pin20: Fuser-IN sensor
Confirm that the above signal levels change
when the sensor lever is operated.
Replace the Fuser-
IN sensor
Check the power
voltages supplied to
the relay PCB.
Check the 5V power voltage at the EXIT
connector of the relay PCB (P6Y. PCB).
pin1: 5V power
3pin, 6pin: 0VL
Replace the
connection cable.
Содержание MC860 MFP
Страница 10: ...43967002TH Rev 1 10 Oki Data CONFIDENTIAL 1 Configuration 1 2 MFP configuration...
Страница 14: ...43967002TH Rev 1 14 Oki Data CONFIDENTIAL 1 Configuration Fig 1 3 Fig 1 4...
Страница 15: ...43967002TH Rev 1 15 Oki Data CONFIDENTIAL 1 Configuration Fig 1 5...
Страница 377: ...Oki Data CONFIDENTIAL 8 Connection Diagrams 8 1 Resistance value check 378 8 2 Parts location 382...