43967002TH Rev.1
139 /
Oki Data CONFIDENTIAL
3. Installation
3.10.2 Turn ON the power
3.10.2.1 Required conditions for power supply
• The following conditions should be satisfied.
AC
: 100V ± 10%
Power frequency : 50 Hz or 60Hz ± 2Hz
• If the power supply is unstable, use the voltage regulator and equivalent.
• Maximum power consumption of this printer is 1,300 W Confirm that the power supply
source has sufficient margin.
• When the UPS (Uninterruptible power supply) is used, operations are not guaranteed. Do
not use the UPS (Uninterruptible power supply).
3.10.2.2 Power switch
1. Connecting the power cord
Warning
Failure to observe the warning may
result in fire and electric shock.
• Before connecting and disconnecting the power cord and earth wire, turn OFF the POWER
switch.
• The earth wire should be connected to the dedicated earth terminal. .
Never connect the earth wire to city water pipe, city gas pipe, earth terminal of telephone line
or lightening rod.
• To disconnect and connect the power cord, be sure to hold the power plug.
• The power plug should be inserted to the deep end of power source connector without fail.
• Do not disconnect and connect the power plug with wet hand.
• Place the power cord to the location where people do not step on it. Do not place any object
on top of the power cord.
• Do not bind nor tie the power cord while using it.
• Do not use the damaged power cord.
• Do not connect many loads on one electrical outlet.
• Do not share the same electrical outlet with other electric products. If air conditioner, copying
machine, paper shredder are connected in parallel, the MFP may malfunction due to electric
noise. If the MFP shares the same electrical outlet with other electric products, use the noise
filter or noise-cut transformer that is available on commercial markets.
• Do not use the AC extension cord. If any extension cord is used by all means, use the exten-
sion cord having rating of 15 A or more.
• If extension cord is used, AC power voltage may drop so that the MFP will not operate nor-
mally.
• Do not turn OFF the power nor disconnect the power plug while printing is in progress.
• When the MFP is not gong to be used for long time due to vacation or trip, disconnect the
power cord.
Note!
If document has been set to the document table before turning ON the
O
I
Earth terminal
Earth wire
Confirm that the POWER switch is set to
OFF (O).
Connect the power cord to the MFP.
Содержание MC860 MFP
Страница 10: ...43967002TH Rev 1 10 Oki Data CONFIDENTIAL 1 Configuration 1 2 MFP configuration...
Страница 14: ...43967002TH Rev 1 14 Oki Data CONFIDENTIAL 1 Configuration Fig 1 3 Fig 1 4...
Страница 15: ...43967002TH Rev 1 15 Oki Data CONFIDENTIAL 1 Configuration Fig 1 5...
Страница 377: ...Oki Data CONFIDENTIAL 8 Connection Diagrams 8 1 Resistance value check 378 8 2 Parts location 382...