43967002TH Rev.1
247 /
Oki Data CONFIDENTIAL
5. Maintenance Menu
• The following messages are displayed during test print.
P Number of test prints (unit: sheet)
W Print wait time (unit: sheet)
• Pressing the (2) key switches the display.
U *** = Upper heater temperature measurement value. [unit: °C]
[###] = Print execute target temperature [unit: °C]
L: *** = Lower thermistor measurement value. [unit: °C]
[###] = Lower thermistor read-out AD value [unit: HEX]
T: Environment temperature measurement value [unit: °C] Environment
humidity measurement value [unit: %]
• Pressing the (2) key switches the display.
YTR, MTR, CTR and KTR are the transfer voltage setting value for each
color. (unit KV)
• Pressing the (2) key switches the display.
KR: BLACK transfer roller resistance value [unit: μA]
YR: YELLOW transfer roller resistance value [unit: μA]
MR: MAGENTA transfer roller resistance value [unit: μA]
CR: CYAN transfer roller resistance value [unit: μA]
• Pressing the (2) key switches the display.
ETMP: Hopping motor standard speed correction parameter (Environment
temperature) [unit: DEC]
UTMP: Fuser motor standard speed correction parameter (Fuser target
temperature) [unit: DEC]
REG: Hopping motor standard speed timer value (I/O setting value) [unit:
HEX]
EXT: Fuser motor standard speed timer value (I/O setting value) [unit: HEX]
• Pressing the (2) key switches the display.
KID, YID, MID and CID are the standard speed timer value for each ID motor
(I/O setting value) [unit: HEX]
• Pressing the (2) key switches the display.
BELT: Belt motor standard speed timer value (I/O setting value) [unit: HEX]
FRM: [***] = Frame thermistor read-out AD value [unit: HEX]
( xxx ) = Frame temperature [unit: °C]
• Pressing the (2) key switches the display.
DB: Develop voltage setup table ID number [unit: HEX]
Содержание MC860 MFP
Страница 10: ...43967002TH Rev 1 10 Oki Data CONFIDENTIAL 1 Configuration 1 2 MFP configuration...
Страница 14: ...43967002TH Rev 1 14 Oki Data CONFIDENTIAL 1 Configuration Fig 1 3 Fig 1 4...
Страница 15: ...43967002TH Rev 1 15 Oki Data CONFIDENTIAL 1 Configuration Fig 1 5...
Страница 377: ...Oki Data CONFIDENTIAL 8 Connection Diagrams 8 1 Resistance value check 378 8 2 Parts location 382...