4. ADJUSTMENT
Oki Data CONFIDENTIAL
44983601TH Rev.1
4-6 /
4.1.2 System maintenance mode (System maintenance menu)
Note!
• This mode is only used by maintenance personnel; it is not released to the end user.
• This mode is only B431.
• Refer to "Maintenance Utility" for B401/B411.
• (*1) can be set by "Maintenance Utility".
To open System Maintenance Menu, hold down the "MENU " and "MENU " button and turn on the power
switch. After the Category has been displayed, let go of the "MENU " and "MENU " button.
Category
Operation panel display
Default
value
Function
* Only English is supported for panel
display
Setting item
(Upper case)
Setting item
(Lower case)
OKIUSER
(*1)
OKIUSER
ODA
OEL
APS
JP1
JPOEM1
OEMA
OEML
*
Set the destination.
JPOEM1: Japan Oriented OEM
OEMA: Overseas OEM for A4 default
OEML: Overseas OEM for Letter default
After passing the MENU, it reboots
automatically. If the Japanese font exist, JP1 is
default.
MAINTENANCE
MENU
FLASH FORMAT EXECUTE
-
Initialize Flash ROM.
After executing it passes the MENU. The
format of Flash Device that is implemented on
resident (on board) starts.
MENU RESET
EXECUTE
-
Reset the EEPROM content to the (Factory
Default) setting value . After the setting
alteration, it reboots automatically.
Part of special item is not initialized.
CONFIG MENU
CODESET
TYPE1
TYPE2
*
This MENU displays as all destination.
TYPE1: Non display of Russian / Grace
TYPE2: Display Russian / Grace.
After passing the MENU, it reboots
automatically.
For destination of OEL/APS/OEMA, TYPE2 is
default value.
For other destinations, TYPE1 is default value.
TEST PRINT
MENU
TEST PRINT
MENU
ENABLE
DISABLE
*
Switch between whether to display ENGINE
INFORMATION that is on the INFORMATION
MENU Category of USER MENU. If this item is
Disable, ENGINE INFORMATION is not often
displayed.
FUSE KEEP
MODE
FUSE KEEP
MODE
EXECUTE
-
While press ENTER Key the command is send
from CU to PU and then it becomes ONLINE.
Replace the consumable by the new one and
check the operation as the power ON. (At this
moment, the fuser of new consumable is not
cut and the operation count is not added to the
value of old consumable.
While turn the power OFF the check mode is
terminated.
Till the next time of power ON it is Disable.