4. ADJUSTMENT
Oki Data CONFIDENTIAL
44983601TH Rev.1
4-27 /
4.1.5 EEPROM Initialization
The treatment for EEPROM Initialization at each phenomenon is displayed as Diagram 4-1.
Diagram 4-1 EEPROM Initial Setting Range
No
Phenomenon
CU EEPROM Area
PU EEPROM Area
Factory
Default
Area
User
Menu
Area
OP
Menu
Area
Administrator Menu/
System Maintenance
Menu Area (*3)
F/W
Revision
Area
Engine Maintenance Menu Area
Brands
Area
Drum
Counter
Page
Counter
Toner
Dot
Counter
1
User Maintenance Menu
EEPROM RESET
Operation
−
−
−
−
−
−
−
−
−
2
F/W Revision check error
at the time of a power on.
−
−
(*4)
−
−
−
−
−
3
CU EEPROM area
mapping
Revision check error at the
time of a power on.
(*4)
−
−
−
−
−
−
4 Brands area check error at
the time of a power on. (*1)
(*4)
−
−
−
−
5 Engine Maintenance Menu
ENGINE RESET
Operation
−
−
−
−
−
−
−
(*2)
(*5)
6
PU EEPROM area
mapping check error at
the time of a power on.
−
−
−
−
−
−
(*3)
7 System Maintenance
Menu
EEPROM RESET
Operation
−
(*4)
−
−
−
−
−
−
(*1) Destination Check is for the operation on the different product (destination) with the previously operated product
(destination). It is the reset relying on the recognition regarding the destination change by PJL command and the
operation at POWER ON of the new product EEPROM as an error.
(*2) It is reset to 0 limited by Page Count less than 500 pieces. (ENGINE RESET due to PJL Command is not in this
limitation.)
(*3) About DOT SHIFT setting menu, even it is also exist in System Maintenance Menu, but because the setting
value keeping area is allocated in PU EEPROM AREA, in the case of the item of System Maintenance Menu
initialized, DOT SHIFT setting is not initialized. By contraries, in the case of PU EEPROM AREA initialized, DOT
SHIFT setting is initialized.
(*4) DOT SHIFT setting should not be initialized.
(*5) Because of the support of Toner TAG, Toner Dot Counter is not reset.
Содержание B431L6
Страница 10: ...Oki Data CONFIDENTIAL 1 CONFIGURATION 44983601TH Rev 1 1 3 B431d B431dn Figure1 3 25...
Страница 31: ...Oki Data CONFIDENTIAL 3 Parts replacement 44983601TH Rev 1 3 4 Figure 3 2 B431d B431dn 25...
Страница 135: ...6 Procedures for Repairing Oki Data CONFIDENTIAL 44983601TH Rev 1 6 26 Figure 6 5 Fuser Assy Contact plate...