Problem
Cause
Solution
In summer, the flow temperature
sensor reading is higher than the
value provided by the heating
curve. This is caused by a
temperature increase in the
heating circuit.
No action required.
The demand for heating is high
due to, for example, a very low
outdoor temperature or, during the
first year, heat required for drying
out the building’s structures.
No action required.
The compressor starts frequently
or stays on for long periods of
time.
Insufficient refrigerant charge.
Check whether there are bubbles
in the sight glass even after
some minutes of use. Contact a
refrigeration or appliance service.
*This type of damage is not covered by the warranty.
5.3 Alarms
Active alarms
When there are active alarms in the system, a bell icon will be displayed in the main
view.
To view active alarms, tap on the bell icon.
Alerts ver. 1
The
Alerts
view shows a list of active alarms in the system.
To acknowledge all active alarms, tap on the bell icon with
strikethrough.
To access the Alarm history view, tap on the recycling button.
Alarm history
To access the heat pump’s
alarm history
, tap on the menu button in
the main view and tap on the
Alarm history
button.
Alternatively, tap on the recycling button in the
Alerts
view.
M8010 2204EN
47 (75)
Содержание ESi 6-17
Страница 2: ......
Страница 62: ...Dimensional drawings ESi 10ESI14_2 ESI 1 ver 1 10ESI14_2 ESI 2 ver 1 60 75 M8010 2204EN...
Страница 63: ...Dimensional drawings EMi 10EMI28T_3 EMI ver 1 M8010 2204EN 61 75...
Страница 64: ...Dimensional drawings ELi 10ELI60T_2 ELI ver 1 62 75 M8010 2204EN...
Страница 78: ...76 75 M8010 2204EN...
Страница 79: ......