Manual control
Cooling - Manual ver. 1
In normal operation, the system will keep the temperature in the brine used for cooling
one degree above the dew point. The purpose of this function is to prevent condensate
from accumulating in any cooling units connected.
● To disable this function, check the Manual checkbox and enter a specific brine
temperature value.
4.7.2 Flexible cooling
Flexible cooling is a versatile solution with a multitude of options for efficient and
effective cooling. The solution has six different operating modes, each described
below.
Flexible cooling ver. 1
Delay
refers to the delay after which the system switches from passive cooling to
active cooling.
Targets temperature
typically refers to room temperature, but can also
refer to an industrial or agricultural process, such as manure slurry channel cooling.
Heating
The ground source heat pump provides heating by transferring thermal energy from the
brine circuit to the storage tank for use in space heating or domestic hot water heating.
Heating and cooling
The ground source heat pump heats up the storage tank by transferring thermal energy
from a brine circuit and a cooling circuit to a storage tank. This mode is in use when
heating and cooling is required at the same time.