11.3 Standard Setting Functions
11.3.1 Standard Setting Functions
Table 11.5
Standard Setting Functions
Function
Description
Burnout
To deflect over toward 100% with disconnecting input. Specifies the every
channel
’s burnout. (DC voltage of ±50mV max., TC input )
Tag Number
Sets a tag number by 7 figures every channel. (Prints at a logging print)
Reference Junction
Compensation
Specifies an inside/outside of the Reference Junction Compensation.
Copy Function
Copies a channel setting up.
Setting input offset
Setting input offset is possible for every channel.
Zone Recording
(Track Recording)
Specifies a recording area every channel to separate into Tracks.
Partial
compression/expansion
Records Partial Compression/Expansion to 1-crease line every channel.
Decade Recording
Indication
Records and indicates by 5 decades. It is 2 figures that the effective number
to indicate and print.
Alarm Print
Prints Occurrence time, Occurrence channel, Setting No. and Alarm type in
purple at occurring an alarm.
Alarm Recovery Print
Prints Recovery time, Recovery channel, Setting No. and Alarm type in purple
at recovering an alarm.
Record Start/end Print
Prints time and comment (
“Start” or ”End”) when record beginning or end.
Computation
Computes Square root.
Interchannel
Computation
Computes Sum, Difference and Average computation.
Alarm Hysteresis Width
Sets an alarm hysteresis width 0% FS or 0.5% FS.
11.4 Optional Functions
11.4.1 Remote Function of DI
Function
Description
Chart Feed Start/Stop
Starts with turning to ON. Stops with turning to OFF.
Changing Chart Speed
Changes 1st with turning to ON and 2nd with OFF.
Comment Print (Sync./Async.)
Prints Comment with turning to ON.
Manual Print (Sync./Async.)
Prints Manual Print with turning to ON.
Date and Time Print (Sync./Async.)
Prints Date and Time with turning to ON.
11.4.2 Alarm Board
6 relays
11.4.3 Communication Unit
RS-232C(Standard)