background image

 
 

 

EN-5

Catapult 1000 Series Scales

NET weight. When removing both the sample and container from the scale, a 
negative value may be displayed. Zero the scale again before subsequent usage. 

 

NOTE: 

The 

ON/ZERO 

Off

 button will perform a true zero setting function when 

displayed values are 2% of full capacity. Above 2%, the range is limited to 
full capacity by subtraction. 
 

3.3 Changing Units of Measure 

Press the 

UNITS 

Cal

 button to display the next available measuring unit.   

 
3.4 Auto Shut-Off 

To extend battery life, the scale will automatically turn off after approximately four 
minutes of inactivity. This feature is only active during battery operation. 

 
3.5 Dynamic Weighing

With the platform empty, short press the 

UNITS 

Cal

 button 

to cycle through the units. Dynamic mode is active when 
the indicator • is flashing.  

 

Place a mass on the platform. The scale will show “-A-”.

 

NOTE: 

If using a container, press 

ON/ZERO 

Off 

to tare the 

weight and return to zero.  
 
With a mass on the platform or container, a short press of 

UNITS 

Cal

 will start the averaging countdown from 5 

seconds. 
 
The averaged weight is then displayed. The indicator • 
stops flashing when the process is complete. 
 
The display will hold until a button is pressed. 
 
To repeat the process press 

UNITS 

Cal

 with a mass on the 

platform or container. 
 
To Exit, remove the mass from the platform or container and 
press 

UNITS 

Cal

 

 

 

 

 

 

 

 

 

 
 

 

Содержание Catapult 1000 Series

Страница 1: ...00 Series TM Instruction Manual Serie Catapult 1000 TM Manual de instrucciones Catapult s rie 1000 TM Manuel d instructions Catapult 1000 Serie TM Bedienungsanleitung Serie Catapult 1000 TM Manuale di...

Страница 2: ......

Страница 3: ...Please follow these safety precautions Verify that the AC Adapter input voltage matches the local AC power supply Do not immerse the scale in water or other liquids Do not operate the scale in hostile...

Страница 4: ...d decimal places Prompts for calibration and possible error conditions are also shown using these digits 1 2 2 Stable Reading Indication A will appear in the lower left corner of the display to indica...

Страница 5: ...eady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes 2 3 Power 2 3 1 AC Power The AC adapter included may be used to power the scale when batter...

Страница 6: ...accordance with local laws and regulations 3 OPERATION 3 1 Turning Scale On Off To turn the scale on press the ON ZERO Off button The scale performs a display test momentarily displays the model soft...

Страница 7: ...s of inactivity This feature is only active during battery operation 3 5 Dynamic Weighing With the platform empty short press the UNITS Cal button to cycle through the units Dynamic mode is active whe...

Страница 8: ...during the entire calibration process Calibration is unavailable in Dynamic Weighing Mode Allow the scale to warm up for at least 2 minutes after stabilizing to room temperature To abort calibration p...

Страница 9: ...using the correct calibration weight 4 2 Calibration Locking By use of an internal switch the calibration function may be locked disabled and unauthorized recalibration prevented With the scale powere...

Страница 10: ...ttery power used up Verify connections and voltage Verify battery polarity Poor accuracy Improper calibration Unstable environment Perform calibration Move scale to suitable location Unable to calibra...

Страница 11: ...E 6 1 SPECIFICATIONS Model C11P9 C11P20 C11P75 Capacity x Readability 9 kg x 0 005 kg 20 lb x 0 01 lb 20 kg x 0 01 kg 44 lb x 0 02 lb 75 kg x 0 05 kg 165 lb x 0 1 lb Weighing Units kg lb Modes Simple...

Страница 12: ...EN 10 Catapult 1000 Series Scales 6 2 Drawings and Dimensions Figure 6 1 Catapult 1000 Series Overall Dimensions...

Страница 13: ...Waste Electrical and Electronic Equipment WEEE this device may not be disposed of in domestic waste This also applies to countries outside the EU per their specific requirements Please dispose of this...

Страница 14: ...ent system is compliant with the ISO 9001 standard s requirements On May 15 2003 Ohaus Corporation USA was re registered to the ISO 9001 2000 standard LIMITED WARRANTY Ohaus products are warranted aga...

Отзывы: