5.3 Service Information  

If the troubleshooting section does not resolve or describe your problem, contact 
your authorized Ohaus service agent. For service assistance or technical support in 
the United States call toll-free 1-800-526-0659 between 8.00 AM and 5:00 PM 
EST. An Ohaus product service specialist will be available to provide assistance. 
Outside the USA, please visit our web site, 

www.ohaus.com

 to locate the Ohaus 

office nearest you.  

 
 

6. TECHNICAL DATA  

The technical data is valid under the following ambient conditions: 
Ambient temperature:  

5°C to 40°C / 41° to 104° F 

Relative humidity:  

10% to 80% relative humidity, non-condensing 

 

6.1 Specifications 

TABLE 6-1. SPECIFICATIONS.  

Model

C11P9

C11P20

C11P75

Capacity x Readability

9 kg x 0.005 kg 

20 lb x 0.01 lb

20 kg x 0.01 kg 

44 lb x 0.02 lb

75 kg x 0.05 kg 

165 lb x 0.1 lb

Weighing Units

kg, lb

Modes

Simple Weighing, Dynamic Weighing

Keypad

2-button mechanical keys

Calibration Weights

9 kg / 20 lb

20 kg / 40 lb

50 kg / 100 lb

Display 

4-digit 7-segment, 20mm / 0.8 in characters

Display Indicators

Stability, weighing unit, dynamic weighing, battery status

Tare range

To capacity by subtraction

Stabilization Time

 3 seconds

Maximum Overload

150%

Operating temperature/humidity 
range

5° to 40°C / 41° to 104°F at 10% to 80% relative humidity, 

non-condensing

Power Requirements

9-12 VDC 100mA AC Adapter (supplied) 

3 “C” Alkaline or rechargeable batteries (LR14) optional

Auto Shut-Off

4 minutes no activity (battery operation only)

Typical Battery life

300 hours

Scale Dimensions (mm / in)

316 x 316 x 60/ 12.4 x 12.4 x 2.36

 
 
 
 
 
 

Содержание Catapult 1000 Series

Страница 1: ...00 Series TM Instruction Manual Serie Catapult 1000 TM Manual de instrucciones Catapult s rie 1000 TM Manuel d instructions Catapult 1000 Serie TM Bedienungsanleitung Serie Catapult 1000 TM Manuale di...

Страница 2: ......

Страница 3: ...Please follow these safety precautions Verify that the AC Adapter input voltage matches the local AC power supply Do not immerse the scale in water or other liquids Do not operate the scale in hostile...

Страница 4: ...d decimal places Prompts for calibration and possible error conditions are also shown using these digits 1 2 2 Stable Reading Indication A will appear in the lower left corner of the display to indica...

Страница 5: ...eady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes 2 3 Power 2 3 1 AC Power The AC adapter included may be used to power the scale when batter...

Страница 6: ...accordance with local laws and regulations 3 OPERATION 3 1 Turning Scale On Off To turn the scale on press the ON ZERO Off button The scale performs a display test momentarily displays the model soft...

Страница 7: ...s of inactivity This feature is only active during battery operation 3 5 Dynamic Weighing With the platform empty short press the UNITS Cal button to cycle through the units Dynamic mode is active whe...

Страница 8: ...during the entire calibration process Calibration is unavailable in Dynamic Weighing Mode Allow the scale to warm up for at least 2 minutes after stabilizing to room temperature To abort calibration p...

Страница 9: ...using the correct calibration weight 4 2 Calibration Locking By use of an internal switch the calibration function may be locked disabled and unauthorized recalibration prevented With the scale powere...

Страница 10: ...ttery power used up Verify connections and voltage Verify battery polarity Poor accuracy Improper calibration Unstable environment Perform calibration Move scale to suitable location Unable to calibra...

Страница 11: ...E 6 1 SPECIFICATIONS Model C11P9 C11P20 C11P75 Capacity x Readability 9 kg x 0 005 kg 20 lb x 0 01 lb 20 kg x 0 01 kg 44 lb x 0 02 lb 75 kg x 0 05 kg 165 lb x 0 1 lb Weighing Units kg lb Modes Simple...

Страница 12: ...EN 10 Catapult 1000 Series Scales 6 2 Drawings and Dimensions Figure 6 1 Catapult 1000 Series Overall Dimensions...

Страница 13: ...Waste Electrical and Electronic Equipment WEEE this device may not be disposed of in domestic waste This also applies to countries outside the EU per their specific requirements Please dispose of this...

Страница 14: ...ent system is compliant with the ISO 9001 standard s requirements On May 15 2003 Ohaus Corporation USA was re registered to the ISO 9001 2000 standard LIMITED WARRANTY Ohaus products are warranted aga...

Отзывы: