B.8 Image control register A#1
Appendix B-5
B.8 Image control register A#1
Image control register B#1
Image control register A#1 /B#1
7 6 5 4 3 2 1 0
0
Automatic separation specification
M3097DE
M3093DE
0× :
Set from the operator panel *1
No operation *2
10 :
Automatic separation is no done
11 :
Automatic separation
Conversion mode specification
Sub-window specification
*1
Bit 7 of the image control register A#2/B#2 and bit 3 of the image control register
A#3/B#3 must be set ‘0’.
*2
Automatic separation specification is same as the status before the command.
B.9 Image control register A#4
Image control register B#4
Image control register A#4 / B#4
7 6 5 4 3 2 1 0
0
0
0
Simplified dynamic threshold specification
M3097DE
M3093DE
0× :
Set from the operator panel
No operation
10 :
Simplified DTC invalid
11 :
Simplified DTC valid
Simplified DTC mode number specification